Inspection Detail
Inspection: 101760130 - National By-Products
Inspection Information - Office: Peoria Area Office
Site Address:
National By-Products
Main Street
Mason City, IL 62664
Mailing Address:
, , 00000
Union Status: Union
SIC:2077
NAICS: 0
Inspection Type: Complaint
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/26/1986
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/03/1987
Type | Activity Nr | Safety | Health |
---|---|---|---|
Complaint | 70945688 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 2 | 4 | 10 | ||
Current Violations | 3 | 4 | 7 | |||
Initial Penalty | $2,400 | $14,000 | $0 | $0 | $0 | $16,400 |
Current Penalty | $1,200 | $0 | $0 | $0 | $0 | $1,200 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 05/15/1986 | 05/27/1986 | $300 | $700 | $0 | 05/19/1986 | F - Formal Settlement | |
2. | 01002 | Serious | 19100215 B09 | 05/15/1986 | 05/20/1986 | $200 | $500 | $0 | 05/19/1986 | F - Formal Settlement | |
3. | 01003 | Serious | 19100305 J04 IIA | 05/15/1986 | 07/21/1986 | $600 | $600 | $0 | 05/19/1986 | F - Formal Settlement | Citation has been deleted. |
4. | 01004 | Serious | 19100305 J04 IIE | 05/15/1986 | 07/21/1986 | $600 | $600 | $0 | 05/19/1986 | F - Formal Settlement | Citation has been deleted. |
5. | 02001 | Willful | 19100303 B01 | 05/15/1986 | 07/21/1986 | $7,000 | $7,000 | $0 | 05/19/1986 | F - Formal Settlement | Citation has been deleted. |
6. | 02002A | Serious | 19100303 G02 I | 05/15/1986 | 07/21/1986 | $700 | $7,000 | $0 | 05/19/1986 | F - Formal Settlement | |
7. | 02002B | Willful | 19100304 E01 V | 05/15/1986 | 07/21/1986 | $0 | $0 | $0 | 05/19/1986 | - | |
8. | 03001 | Other | 19100110 C06 III | 05/15/1986 | 05/20/1986 | $0 | $0 | $0 | 05/19/1986 | F - Formal Settlement | |
9. | 03002 | Other | 19100157 G01 | 05/15/1986 | 05/21/1986 | $0 | $0 | $0 | 05/19/1986 | F - Formal Settlement | |
10. | 03003 | Other | 19100304 A02 | 05/15/1986 | 05/21/1986 | $0 | $0 | $0 | 05/19/1986 | F - Formal Settlement | |
11. | 03004 | Other | 19100305 B01 | 05/15/1986 | 05/20/1986 | $0 | $0 | $0 | 05/19/1986 | F - Formal Settlement |
Investigation Summary
An employee was closing a circuit breaker, and it failed. The ensuing electric arc burned the employee. He was hospitalized with second- and third-degree burns to his chest, neck, face, right hand, and right arm and with burns to his eyes. The circuit breakers were designed to be secured by four screws, but were only secured by two.
Keywords: BURN, CHEST, CLOTHING, E GI V, ELECTRIC ARC, ELECTRICAL, EQUIPMENT FAILURE, CIRCUIT BREAKER, ELECTRICAL FAULT, FACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101760130 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |