Powered by GoogleTranslate

Inspection Detail

Inspection: 101759124 - Chestnut Mountain Resort, Incorporated

Inspection Information - Office: Naperville Area Office

 

Inspection Nr: 101759124
Report ID: 0521400
Date Opened: 07/30/1986

Site Address:
Chestnut Mountain Resort, Incorporated
8700 West Chestnut
Galena, IL 61036

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/30/1986

Emphasis:

Case Closed: 10/03/1986


Related Activity
Type Activity Nr Safety Health
Accident 360562789
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $420 $0 $0 $0 $0 $420
Current Penalty $300 $0 $0 $0 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260400 C01 08/25/1986 09/02/1986 $300 $420 $0 I - Informal Settlement  
2. 01001B Serious 19260400 C02 08/25/1986 09/02/1986 $0 $0 $0 -  
3. 01001C Serious 19260450 A11 08/25/1986 09/02/1986 $0 $0 $0 -  
4. 02001 Other 19260400 A 08/25/1986 09/02/1986 $0 $0 $0 -  
5. 02002 Other 19260402 C03 08/25/1986 09/02/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14382535
Event: 07/28/1986
ELECTRIC SHOCK - CONTACT WITH ENERGIZED CONDUCTOR

Some employees were moving an outdoor light and pole to a new location for a new rope tow at a ski resort. The employees had hung the cable for a Hedco snowmaker and secured the cable for the lighting fixture. One of the employees was working from an aluminum ladder, securing the lighting fixture to the pole. The fixture fell and cut into the cable for the snowmaker. The cable for the snowmaker was energized, and the fixture became energized when it penetrated the cable. The employee, who and was still holding onto the fixture, was electrocuted.

Keywords: ELEC INSULATION, E GI IV, ELECTRICAL, ELECTRIC CABLE, ELECTROCUTED, LADDER, LIGHTING FIXTURE, ELECTRICAL WORK, LOCKOUT, METAL LADDER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101759124 Fatality Electric Shock Not specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.