Powered by GoogleTranslate

Inspection Detail

Inspection: 101744647 - Superior Products Co.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 101744647
Report ID: 0420600
Date Opened: 04/21/1987

Site Address:
Superior Products Co.
505 10th Street East
Palmetto, FL 33561

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3272

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/27/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/16/1987


Related Activity
Type Activity Nr Safety Health
Accident 360727440
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 12 14
Current Violations 2 12 14
Initial Penalty $1,260 $0 $0 $450 $0 $1,710
Current Penalty $1,260 $0 $0 $450 $0 $1,710
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B01 05/20/1987 06/04/1987 $630 $630 $0 -  
2. 01002 Serious 19100304 F05 VC 05/20/1987 06/04/1987 $630 $630 $0 -  
3. 02001 Other 19040002 A 05/20/1987 06/04/1987 $90 $90 $0 -  
4. 02002 Other 19040008 05/20/1987 05/26/1987 $360 $360 $0 -  
5. 02003 Other 19100132 A 05/20/1987 06/04/1987 $0 $0 $0 -  
6. 02004 Other 19100179 J02 05/20/1987 06/04/1987 $0 $0 $0 -  
7. 02005 Other 19100179 J03 05/20/1987 06/04/1987 $0 $0 $0 -  
8. 02006 Other 19100184 E03 I 05/20/1987 06/04/1987 $0 $0 $0 -  
9. 02007 Other 19100252 A02 IVC 05/20/1987 06/04/1987 $0 $0 $0 -  
10. 02008 Other 19100304 F04 05/20/1987 06/04/1987 $0 $0 $0 -  
11. 02009 Other 19101200 E01 05/20/1987 06/24/1987 $0 $0 $0 -  
12. 02010 Other 19101200 F04 I 05/20/1987 06/24/1987 $0 $0 $0 -  
13. 02011 Other 19101200 G01 05/20/1987 06/24/1987 $0 $0 $0 -  
14. 02012 Other 19101200 H 05/20/1987 06/24/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14516439
Event: 04/17/1987
ELECTRIC SHOCK - GROUND FAULT IN ATTACHMENT PLUG

A MACHINE OPERATOR WAS OPERATING A PIPE MACHINE THAT WAS USED TO MANUFACTURE CONCRETE PIPE PRODUCTS. THREE FORMS HAD BEEN MOUNTED ON A 12-FOOT-DIAMETER PLATFORM. TWO OF THE FORMS HAD VIBRATORS MOUNTED ON THEIR SIDES TO SETTLE THE POURED CONCRETE. THE 240-VOLT, THREE-PHASE VIBRATORS WERE CONNECTED TO THEIR SUPPLY BY HEAVY FLEXIBLE POWER CORDS. AN ATTACHMENT PLUG ON AN EXTENSION CORD SET SUPPLYING ONE OF THE POWER CORDS WAS MISWIRED IN SUCH A MANNER AS TO ENERGIZE THE FRAME OF THE VIBRATOR (AND ALL METAL OBJECTS BONDED TO IT). THE MACHINE OPERATOR WAS ELECTROCUTED WHILE HE WAS OPERATING THE MACHINE.

Keywords: ELECTRICAL, CORD SET, E GI VII, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, EQUIPMENT GROUNDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101744647 Fatality Electric Shock Fabricating machine operators, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.