Powered by GoogleTranslate

Inspection Detail

Inspection: 101692408 - Tech Ii, Inc.

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 101692408
Report ID: 0522000
Date Opened: 04/17/1986

Site Address:
Tech Ii, Inc.
1765 W. County Line Road
Springfield, OH 45501

Mailing Address:
P.O. Box 1468, Springfield, OH 45501

Union Status: NonUnion

SIC:3089

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/23/1986

Emphasis:

Case Closed: 08/19/1987


Related Activity
Type Activity Nr Safety Health
Accident 360543045
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $420 $0 $0 $0 $0 $420
Current Penalty $420 $0 $0 $0 $0 $420
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19101000 A02 05/12/1986 05/15/1986 $420 $420 $0 -  
2. 01001B Serious 19101000 E 05/12/1986 05/15/1986 $0 $0 $0 -  
3. 02001 Other 19100020 G02 05/12/1986 05/16/1986 $0 $0 $0 -  
4. 02002 Other 19100132 A 05/12/1986 05/27/1986 $0 $0 $0 -  
5. 02003 Other 19100151 C 05/12/1986 05/16/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 570127
Event: 04/15/1986
Ten employees overexposed to carbon monoxide

Lid and bowl printers had been moved to a new location over two to four weeks, installed, and put into operation. The printers use a propane burner to heat plastic lids or bowls before printing with UV cured inks. The ventilation system had not been reinstalled. Apparently, at the beginning of the third shift, midnight to 8:30 a.m., the air conditioning system was turned off because it was cold, and a Clark forklift B55244045 was in the area. Employees #1 through #10 started to experience headaches between 5:00 and 6:30 a.m. The employees met in the rest room and all were suffering from headaches, nausea, and dizziness. At 8:00 a.m., all employees except Employee #10 went outside. All ten employees, except Employees #2 and #3, who went to a family doctor, went to the hospital for blood tests. The employer was notified of the carbon monoxide overexposure and told other employees to report to hospitals.

Keywords: VENTILATION, HEADACHE, WORK RULES, INHALATION, NAUSEA, INDUSTRIAL TRUCK, EXHAUST FUMES, TOXIC FUMES, OVEREXPOSURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101692408 Hospitalized injury Asphyxia Occupation not reported
2 101692408 Hospitalized injury Asphyxia Occupation not reported
3 101692408 Hospitalized injury Asphyxia Occupation not reported
4 101692408 Hospitalized injury Asphyxia Occupation not reported
5 101692408 Hospitalized injury Asphyxia Occupation not reported
6 101692408 Hospitalized injury Asphyxia Occupation not reported
7 101692408 Hospitalized injury Asphyxia Occupation not reported
8 101692408 Hospitalized injury Asphyxia Occupation not reported
9 101692408 Hospitalized injury Asphyxia Occupation not reported
10 101692408 Hospitalized injury Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.