Inspection Detail
Inspection: 1016844.015 - Capitol Engineering Laboratories Inc
Inspection Information - Office: Redding District Office
Site Address:
Capitol Engineering Laboratories Inc
2593 New Navy Base Rd (Hwy 255)
Arcata, CA 95521
Mailing Address:
Po Box 729, Foresthill, CA 95631
Union Status: NonUnion
SIC:
NAICS: 541380/Testing Laboratories
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/22/2015
Emphasis:
Case Closed: 05/11/2015
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 930883 |
Investigation Summary
At 8:45 p.m. on January 6, 2015, an employee was inspecting a Genie S-60 aerial lift when it came into proximity of a 60 kv powerline and he was electrocuted.
Keywords: Aerial Lift, Electrocuted, Overhead Power Line, Power Lines
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1016844.015 | 64 | M | Fatality | Mechanical engineers |