Inspection Detail
Inspection: 101587244 - Tampa Shipyards, Incorporated
Inspection Information - Office: Tampa Area Office
Site Address:
Tampa Shipyards, Incorporated
113 Mccloskey Blvd.
Tampa, FL 33605
Mailing Address:
, , 00000
Union Status: Union
SIC:3731
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/05/1986
Planning Guide: Safety-Maritime
Emphasis:
Case Closed: 09/22/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 901019703 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $800 | $0 | $0 | $0 | $0 | $800 |
| Current Penalty | $800 | $0 | $0 | $0 | $0 | $800 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01003 | Serious | 19150052 B02 | 03/14/1986 | 03/18/1986 | $800 | $800 | $0 | 04/09/1986 | R - Review Commission |
Investigation Summary
EMPLOYEES #1 AND #2, A WELDER AND A PIPEFITTER RESPECTIVELY, WERE WORKING IN THE FAN ROOM OF A VESSEL UNDER CONSTRUCTION. DURING THE PREVIOUS NIGHT, SOMEONE HAD LEFT A CAN OF PAINT THINNER IN THE ROOM. WHILE CRAWLING IN THE ROOM, EMPLOYEE #1 TOUCHED HIS WELDING ROD TO THE CAN AND IT EXPLODED. BOTH EMPLOYEES WERE HOSPITALIZED FOR BURNS.
Keywords: FLAMMABLE VAPORS, FIRE, WELDER, EXPLOSION, PAINT SOLVENT, SHIP, WELDING ELECTRODE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101587244 | Hospitalized injury | Burn/Scald(Heat) | Welders and cutters | ||
| 2 | 101587244 | Hospitalized injury | Burn/Scald(Heat) | Welders and cutters |