Inspection Detail
Inspection: 101586980 - Florida Power Corporation
Inspection Information - Office: Tampa
Site Address:
Florida Power Corporation
Crystal River Plant #3 Power Line Road
Crysta River, FL 32629
Mailing Address:
, , 00000
Union Status: Union
SIC:7389
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 01/29/1986
Emphasis:
Case Closed: 02/03/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360146260 |
Investigation Summary
TWO COMMERCIAL DIVERS WERE KILLED WHEN THEY WERE DRAWN INTO AN INTAKE PIPE WHICH CARRIED COOLING WATER TO A NUCLEAR REACTOR IN AN ELECTRIC GENERATING PLANT. THE PUMPING SYSTEM HAD BEEN MISTAKENLY LEFT RUNNING WHILE THE DIVERS WERE ENGAGED IN CLEANING AND INSPECTING ACTIVIES. DESPITE THE POOR VISIBILITY AND THE RESTRICTED CONFIGURATION OF THE WORK AREA, THE DIVERS WERE USING SCUBA GEAR WITH NO SURFACE LINE TENDING. SINCE ACCESS INTO THE DIVE AREA WAS THROUGH A MANHOLE, NO ONE TOPSIDE COULD MONITOR THE LOCATION OF THE INWATER DIVER. WHEN THE FIRST DIVER FAILED TO REAPPEAR IN A TIMELY FASHION, THE SECOND DIVER ENTERED THE WATER TO BEGIN A SEARCH FOR HIM. THE RESCUE DIVER ALSO BECAME TRAPPED IN THE MECHANICALLY INDUCED CURRENTS. ONLY AFTER THE PUMPS WERE SHUT DOWN WERE THE BODIES RECOVERED.
Keywords: SCUBA, DIVING, PIPE, DROWN, MANHOLE, DIVER, COMMERCIAL DIVING, POOR VISIBILITY
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101586980 | Occupation Not Listed |