Inspection Detail
Inspection: 101556447 - Doby Of Dade Supply Company
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Doby Of Dade Supply Company
9838 Nw 2nd Court
Plantation, FL 33324
Mailing Address:
120 W. Glade Rd., Plantation, FL 33324
Union Status: NonUnion
SIC:5211
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/18/1986
Emphasis:
Case Closed: 03/05/1987
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360143044 |
Investigation Summary
A TRUCK DRIVER WAS DELIVERING A LOAD OF DRYWALL TO A HOUSING PROJECT. THE LOAD WAS ON THE BED OF A BOOM TRUCK. HE ARRIVED AT THE REAR OF THE HOUSING PROJECT AND WAS GOING TO UNLOAD THE DRYWALL TO AN EMPLOYEE AT A SECOND STORY WINDOW OF ONE OF THE BUILDINGS AT THE SITE. A 13-KILOVOLT OVERHEAD POWER LINE WAS LOCATED ABOUT 13 FEET FROM THE BUILDING. THE TRUCK DRIVER TRIED TO MANEUVER THE LOAD BENEATH THE OVERHEAD LINE AND FOUND THAT IT WAS NOT POSSIBLE TO DELIVER THE LOAD FROM THIS DIRECTION. HE THEN LIFTED THE LOAD WITH THE BOOM BETWEEN THE OVERHEAD CONDUCTORS. APPARENTLY, AS HE WAS WITHDRAWING THE BOOM FROM BETWEEN THE CONDUCTORS, IT CONTACTED THE OVERHEAD LINE, ELECTROCUTING THE TRUCK DRIVER.
Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E GI IA
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101556447 | Fatality | Electric Shock | Truck drivers, heavy |