Inspection Detail
Inspection: 101362937 - San Jose Plumbing Company
Inspection Information - Office: Jacksonville Area Office
Site Address:
San Jose Plumbing Company
4700 Ortega Hills Drive
Jacksonville, FL 32244
Mailing Address:
12550 Remler Dr. West, Jacksonville, FL 32223
Union Status: NonUnion
SIC:7699
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 09/20/1988
Emphasis:
Case Closed: 08/09/1990
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360127062 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 5 | 8 | |||
Current Violations | 3 | 5 | 8 | |||
Initial Penalty | $600 | $0 | $0 | $0 | $0 | $600 |
Current Penalty | $200 | $0 | $0 | $0 | $0 | $200 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100212 A04 | 10/11/1988 | 10/17/1988 | $100 | $200 | $0 | 11/02/1988 | R - Review Commission | |
2. | 01002 | Serious | 19100219 E03 I | 10/11/1988 | 10/27/1988 | $50 | $200 | $0 | 11/02/1988 | R - Review Commission | |
3. | 01003 | Serious | 19100305 G02 II | 10/11/1988 | 10/17/1988 | $50 | $200 | $0 | 11/02/1988 | R - Review Commission | |
4. | 02001 | Other | 19101200 E01 | 10/11/1988 | 11/14/1988 | $0 | $0 | $0 | 11/02/1988 | - | |
5. | 02002 | Other | 19101200 F04 I | 10/11/1988 | 11/14/1988 | $0 | $0 | $0 | 11/02/1988 | - | |
6. | 02003 | Other | 19101200 F04 II | 10/11/1988 | 11/14/1988 | $0 | $0 | $0 | 11/02/1988 | - | |
7. | 02004 | Other | 19101200 G01 | 10/11/1988 | 11/14/1988 | $0 | $0 | $0 | 11/02/1988 | - | |
8. | 02005 | Other | 19101200 H | 10/11/1988 | 11/14/1988 | $0 | $0 | $0 | 11/02/1988 | - |
Investigation Summary
A PLUMBER'S HELPER WAS ASSISTING HIS EMPLOYER IN OPENING A CLOGGED SEWER PIPE IN AN APARTMENT COMPLEX. HE WAS STANDING IN A SHALLOW EXCAVATION TO PULL FLEXIBLE COIL FROM THE ROTATING BASKET OF A ROOTER-TYPE SEWER MACHINE AND FORCE IT ALONG THE SEWER LINE. THE EMPLOYER HAD BEEN OPERATING THE MACHINE BY MEANS OF ITS CONTROL BOX, WHICH WAS ATTACHED TO THE MACHINE THROUGH A LONG CORD. WHEN THE EMPLOYER PLACED THE CONTROLLER DOWN AND WENT AROUND THE BUILDING TO CHECK PROGRESS AT A CLEAN OUT OPENING, THE EMPLOYEE PICKED UP THE CONTROLLER AND BEGAN TO OPERATE THE MACHINE HIMSELF. BECAUSE OF THE EMPLOYEE'S POSITION IN THE EXCAVATION, THE CONTROLLER CORD BECAME ENTANGLED WITH THE ROTATING BASKET, DAMAGING THE INSULATION AND EXPOSING THE CONDUCTORS. THE ENERGIZED CONDUCTORS CONTACTED THE METAL BASKET, ENERGIZING IT AND THE ATTACHED FLEXIBLE METAL COIL. THE EMPLOYEE, WHO WAS STILL HOLDING THE COIL, WAS ELECTROCUTED. THE EMPLOYEE HAD BEEN WORKING AT THIS JOB FOR 8.5 MONTHS AND HAD HAD NO SAFETY TRAINING.
Keywords: E GI III, ELECTRICAL, ELECTROCUTED, GROUND FAULT, WET OPERATION, EQUIPMENT GROUNDING, ELEC EQUIPMENT--MISC
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101362937 | Fatality | Electric Shock | Plumber, pipefitter and steamfiter apprentices |