Inspection Detail
Inspection: 101330215 - Corcom Inc.
Inspection Information - Office: Chicago North Area Office
Site Address:
Corcom Inc.
1600 Winchester Road
Libertyville, IL 60048
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3679
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/14/1988
Emphasis:
Case Closed: 03/31/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360357511 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 2 | 7 | |||
| Current Violations | 5 | 2 | 7 | |||
| Initial Penalty | $2,300 | $0 | $0 | $200 | $0 | $2,500 |
| Current Penalty | $2,300 | $0 | $0 | $200 | $0 | $2,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 11/23/1988 | 11/26/1988 | $1,000 | $1,000 | $0 | - | ||
| 2. | 01002 | Serious | 19100038 A01 | 11/23/1988 | 01/26/1989 | $200 | $200 | $0 | - | ||
| 3. | 01003 | Serious | 19100157 G01 | 11/23/1988 | 01/26/1989 | $300 | $300 | $0 | - | ||
| 4. | 01004 | Serious | 19101200 H | 11/23/1988 | 01/26/1989 | $400 | $400 | $0 | - | ||
| 5. | 01005 | Serious | 19101200 E01 | 11/23/1988 | 01/26/1989 | $400 | $400 | $0 | - | ||
| 6. | 02001 | Other | 19040002 A | 11/23/1988 | 12/23/1988 | $100 | $100 | $0 | - | ||
| 7. | 02002 | Other | 19040004 | 11/23/1988 | 12/23/1988 | $100 | $100 | $0 | - |
Investigation Summary
AN EMPLOYEE WALKED UP TO A RAYTHEON (MODEL NO. GS-1200) LASER WELDER THAT WAS BEING INSTALLED. HE STOOD BEHIND THE TWO PERSONS WHO WERE COMPLETING THE INSTALLATION AND CLEANING THE MIRRORS. THE EMPLOYEE DID NOT SPEAK TO THE TWO INSTALLERS. HE PLACED HIS LEFT ARM ON THE GROUNDED FRAME OF THE MACHINE WHILE HE WAS STANDING IN FRONT OF UNGUARDED CIRCUIT BOARDS THAT WERE ENERGIZED AT 20 KILOVOLTS. APPARENTLY, THERE WAS AN ELECTRIC ARC, ELECTROCUTING THE EMPLOYEE. THE EMPLOYEES HAD BEEN WARNED TO STAY AWAY FROM THE MACHINE DURING INSTALLATION; HOWEVER, THE ENERGIZED PARTS OF THE MACHINE WERE NOT GUARDED NOR WERE BARRICADES INSTALLED AROUND THE WORK AREA.
Keywords: ELECTRICAL, UNTRAINED, ELEC PROTECT EQUIP, E GI III, ELECTROCUTED, LOCKOUT, UNGUARDED LIVE PARTS, ELEC CIRC PART--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101330215 | Fatality | Electric Shock | Occupation not reported |