Inspection Detail
Inspection: 101305084 - Big "H" Drilling, Inc.
Inspection Information - Office: Omaha Area Office
Site Address:
Big "H" Drilling, Inc.
2 Miles North, 1 Mile East Of Hwy. #6
Mccook, NE 69001
Mailing Address:
400 One Main Place, Wichita, KS 67202
Union Status: NonUnion
SIC:1382
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/31/1988
Emphasis:
Case Closed: 10/11/1988
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360383293 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 2 | 3 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $280 | $0 | $0 | $0 | $0 | $280 |
Current Penalty | $280 | $0 | $0 | $0 | $0 | $280 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100303 B01 | 09/08/1988 | 09/15/1988 | $280 | $280 | $0 | - | ||
2. | 02001 | Other | 19040008 | 09/08/1988 | 09/15/1988 | $0 | $0 | $0 | - | ||
3. | 02002 | Other | 19101200 E01 | 09/08/1988 | 10/07/1988 | $0 | $0 | $0 | - |
Investigation Summary
An employee had unplugged a 240-volt, three-phase electric motor for a portable pump. He changed connections to direct the water flow and plugged the pump back into an electric cord. The pins on the connectors were not properly aligned, and the employee was electrocuted.
Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, ELECTRIC PUMP, GROUND FAULT, CORD CONNECTOR, EQUIPMENT GROUNDING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101305084 | Fatality | Electric Shock | Occupation not reported |