Inspection Detail
Inspection: 101304616 - Concrete Placement, Inc.
Inspection Information - Office: Kansas City Area Office
Site Address:
Concrete Placement, Inc.
1802 Melville Road
Springfield, MO 65801
Mailing Address:
820 Cheyenne, Kansas City, KS 66105
Union Status: NonUnion
SIC:1771
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/01/1988
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/14/1988
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $640 | $0 | $0 | $0 | $0 | $640 |
Current Penalty | $640 | $0 | $0 | $0 | $0 | $640 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260600 A06 | 09/26/1988 | 09/29/1988 | $640 | $640 | $0 | - |
Investigation Summary
A CONCRETE PUMPER TRUCK CONCRETE PLACEMENT FIRM WAS DELIVERING CONCRETE TO A DRAINAGE DITCH. THE CONCRETE TRUCK OPERATOR WAS USING THE TRUCK'S BOOM EXTENDED OVER A ROAD TO POUR THE CONCRETE. TWO EMPLOYEES OF A DIFFERENT CONCRETE COMPANY WERE HANDLING THE HOSE AT THE END OF THE BOOM TO DIRECT THE PLACEMENT OF THE CONCRETE. THE BOOM CONTACTED A 7620-VOLT OVERHEAD POWER LINE. THE TWO EMPLOYEES HOLDING THE HOSE RECEIVED ELECTRIC SHOCKS. ONE OF THEM WAS ELECTROCUTED; THE OTHER RECEIVED SEVERE BURNS AND WAS HOSPITALIZED IN CRITICAL CONDITION.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, CONCRETE TRUCK, E GI IA, TRUCK BOOM, BOOM, ELECTROCUTED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101304616 | Occupation Not Listed |