Powered by GoogleTranslate

Inspection Detail

Inspection: 101280873 - Georgia Power Company

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 101280873
Report ID: 0418100
Date Opened: 09/24/1987

Site Address:
Georgia Power Company
Plant Yates, Hwy 16 W
Newnan, GA 30264

Mailing Address:
P.O. Box 718, Newnan, GA 30264

Union Status: Union

SIC:4911

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/05/1987

Emphasis:

Case Closed: 09/28/1988


Related Activity
Type Activity Nr Safety Health
Accident 360126478
Complaint 71544647 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $1,470 $0 $0 $0 $0 $1,470
Current Penalty $900 $0 $0 $0 $0 $900
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100023 A07 10/21/1987 10/24/1987 $300 $490 $0 11/15/1987 F - Formal Settlement  
2. 01002 Serious 19100025 D02 I 10/21/1987 10/24/1987 $300 $490 $0 11/15/1987 F - Formal Settlement  
3. 01003 Serious 19100132 A 10/21/1987 10/24/1987 $300 $490 $0 11/15/1987 F - Formal Settlement  

Investigation Summary

Investigation Nr: 608505
Event: 09/23/1987
FALL THROUGH UNGUARDED FLOOR OPENING

An apprentice electrician at an electric utility was looking for a faulty lighting fixture that he and a coworker had been assigned to repair. He entered an area that had been barricaded with tape and rope, where two mechanics were replacing sections of grating. The existing grating had been temporarily removed. There was an 864-millimeter by 711-millimeter opening where the last section of grating was to be placed. After speaking briefly with the mechanics, the apprentice crossed over the opening to ask another person about the lighting. While talking to this person, the apprentice had his back to the opening. Afterwards, he turned and stepped into the opening, falling 14 meters feet to the ground. He died of his injuries.

Keywords: UNGUARDED FL OPENING, GRATING, WALKING SURFACE, FALL, FALL PROTECTION, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101280873 Fatality Fracture Electricians' apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.