Inspection: 101275758 - Boyd Cochran & Sons/Dba/House Movers, Inc.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 101275758
Report ID: 0418100
Date Opened: 05/27/1988

Site Address:
Boyd Cochran & Sons/Dba/House Movers, Inc.
Ken Due West Road Ne At Acworth Due West Road Ne
Marietta, GA 30064

Mailing Address:
501 Hazel Lane, Calhoun, GA 30701

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/18/1988

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/31/1988


Related Activity
Type Activity Nr Safety Health
Accident 360564678
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $210 $0 $0 $0 $0 $210
Current Penalty $210 $0 $0 $0 $0 $210
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 A01 08/25/1988 08/28/1988 $210 $210 $0 -  

Investigation Summary

Investigation Nr: 608364
Event: 05/27/1988
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

A HOUSE MOVING CONTRACTOR WAS MOVING A STRUCTURE. TWO EMPLOYEES WERE RIDING ATOP THE STRUCTURE TO MOVE CABLES OUT OF THE WAY AS THE STRUCTURE TRAVELED ALONG THE STREET. THE STRUCTURE'S ROOF RIDGE CONTACTED A TELEPHONE CABLE, AND THE RIG CAME TO A STOP TO ENABLE ONE OF THE EMPLOYEES ON THE STRUCTURE TO EASE THE CABLE OVER TO THE SIDE OF THE GABLE END OF THE ROOF. ONE OF THESE TWO EMPLOYEES WAS INSTRUCTED BY THE EMPLOYER AND THREE COWORKERS TO STAY CLEAR OF A 7.2-KILOVOLT OVERHEAD POWER LINE THAT WAS LOCATED DIRECTLY ABOVE THE TELEPHONE LINE. HE WAS ALSO INSTRUCTED TO SIT ON THE ROOF AND PUSH THE TELEPHONE LINE. THE EMPLOYEE, INSTEAD, STOOD UP, REACHED DOWN AND PICKED UP THE TELEPHONE LINE. HIS HEAD CONTACTED THE POWER LINE, AND HE WAS ELECTROCUTED. (HE WAS NOT WEARING ANY ELECTRICAL PROTECTIVE EQUIPMENT.)

Keywords: STRUCTURE MOVING, HEAD, E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101275758 Fatality Electric Shock Construction trades, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.