Powered by GoogleTranslate

Inspection Detail

Inspection: 101271567 - Register Construction & Engineering, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 101271567
Report ID: 0420600
Date Opened: 09/04/1987

Site Address:
Register Construction & Engineering, Inc.
940 County Line Road
Lakeland, FL 33801

Mailing Address:
3730 New Tampa Hwy., Lakeland, FL 33801

Union Status: NonUnion

SIC:1541

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/24/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/21/1988


Related Activity
Type Activity Nr Safety Health
Accident 360707491

Investigation Summary

Investigation Nr: 14516959
Event: 09/04/1987
CONCRETE TILT-UP WALL STRUCK & KILLED CONSTRUCTION WORKER

EMPLOYEE #1, AN IRONWORKER, WAS STANDING ON BAR JOISTS THAT HAD BEEN INSTALLED FOR THE ROOF OF A LARGE WAREHOUSE. THE WALLS OF THE WAREHOUSE WERE TILT-UP CONCRETE WALL CONSTRUCTION. THE BAR JOISTS HAD BEEN SET IN POCKETS ON THE CONCRETE WALLS. THE WALLS WERE SUPPORTED BY DIAGONAL BRACES. BUNDLES OF FLOOR DECKING WERE STACKED ON THE BAR JOISTS. THE BAR JOISTS WERE NOT WELDED IN THE WALL POCKETS. A BAR JOIST ROLLED AND FELL OUT OF THE POCKET. THIS ACTION CAUSED EMPLOYEE #1 TO FALL 37 FEET TO THE FLOOR BELOW. HE HUNG ONTO THE WALL SECTION THAT FELL AWAY AWAY FROM THE BUILDING. AT THE SAME TIME, A SERIES OF BAR JOISTS RAPIDLY FELL, STRIKING THE WALLS AND DIAGONAL BRACES. A SECOND WALL SECTION, WEIGHING APPROXIMATELY 30,000 POUNDS, FELL ON EMPLOYEE #1, WHO WAS THEN ON THE GROUND. HE WAS KILLED. NO OTHER WALL SECTIONS FELL.

Keywords: BRACE, FALL, STRUCK BY, WALL, UNSECURED, IRON WORKER, CONSTRUCTION, FALLING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101271567 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.