Inspection: 101268688 - Gulfcoast Boring & Pipeline Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 101268688
Report ID: 0420600
Date Opened: 09/29/1987

Site Address:
Gulfcoast Boring & Pipeline Inc.
U.S. 27 & Crump Road
Lake Hamilton, FL 33851

Mailing Address:
4015 Holden Road, Lakeland, FL 33811

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/02/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/14/1987


Related Activity
Type Activity Nr Safety Health
Referral 900902727 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $500 $0 $0 $0 $0 $500
Current Penalty $500 $0 $0 $0 $0 $500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 10/08/1987 10/11/1987 $250 $250 $0 -  
2. 01002 Serious 19260550 A15 II 10/08/1987 10/11/1987 $250 $250 $0 -  
3. 02001 Other 19260020 B01 10/08/1987 10/14/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14516900
Event: 09/28/1987
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU CRANE BOOM

THREE EMPLOYEES WERE SETTING STEEL PIPES IN A DITCH. THEY WERE INSERTING A STEEL AUGER INTO ONE OF THE 16-FOOT-LONG PIPES. TWO EMPLOYEES WERE GUIDING THE AUGER INTO POSITION AS IT WAS BEING TRANSPORTED BY A CRANE. THE CRANE'S BOOM WAS POSITIONED ABOUT 2 FEET BELOW A 7200-VOLT OVERHEAD POWER LINE; AND, WHEN THE BOOM WAS RAISED, IT CONTACTED THE OVERHEAD LINE. ONE OF THE EMPLOYEES, WHO WAS GUIDING THE AUGER WHILE HOLDING ONTO THE CHAIN SLING, RECEIVED AN ELECTRIC SHOCK, WHICH KNOCKED HIM DOWN. THE OTHER EMPLOYEE GUIDING THE AUGER RAN OVER TO HELP THE INJURED EMPLOYEE, AND HE ALSO RECEIVED AN ELECTRIC SHOCK, WHICH KNOCKED HIM DOWN. THE CRANE OPERATOR THEN JUMPED OUT OF THE CRANE AND RAN OVER TO DRAG THE FIRST INJURED EMPLOYEE AWAY FROM THE AREA. HE ALSO RECEIVED AN ELECTRIC SHOCK. THE CRANE OPERATOR AND THE SECOND INJURED EMPLOYEE WERE HOSPITALIZED FOR THEIR INJURIES. THE OTHER EMPLOYEE, ALTHOUGH HE WAS NOT HOSPITALIZED, WAS SERIOUSLY INJURED ON HIS LEFT HAND AND NEEDED SURGERY AND OTHER MEDICAL TREATMENT. ALL THREE EMPLOYEES WERE VERY YOUNG AND HAD INSUFFICIENT KNOWLEDGE OF ELECTRICAL HAZARDS.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E C, ELECTRIC SHOCK, UNTRAINED, HAND, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101268688 Non Hospitalized injury Electric Shock Occupation not reported
2 101268688 Hospitalized injury Electric Shock Occupation not reported
3 101268688 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.