Powered by GoogleTranslate

Inspection Detail

Inspection: 101250819 - Kemanord, Inc.

Inspection Information - Office: Jackson Area Office

 

Inspection Nr: 101250819
Report ID: 0419400
Date Opened: 07/31/1987

Site Address:
Kemanord, Inc.
Nashville Ferry Road
Columbus, MS 39701

Mailing Address:
P. O. Box 2167, Columbus, MS 39704

Union Status: Union

SIC:2819

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/18/1987

Emphasis:

Case Closed: 01/13/1988


Related Activity
Type Activity Nr Safety Health
Accident 360131445
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 3 3 6
Initial Penalty $1,260 $0 $0 $0 $0 $1,260
Current Penalty $850 $0 $0 $0 $0 $850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 09/09/1987 09/14/1987 $300 $490 $0 10/06/1987 F - Formal Settlement  
2. 01002A Serious 19101200 E01 II 09/09/1987 10/05/1987 $300 $420 $0 10/06/1987 F - Formal Settlement  
3. 01002B Serious 19101200 E01 III 09/09/1987 10/02/1987 $0 $0 $0 10/06/1987 -  
4. 01002C Serious 19101200 H01 09/09/1987 10/02/1987 $0 $0 $0 10/06/1987 -  
5. 01003 Serious 19100134 D03 09/09/1987 10/14/1987 $250 $350 $0 10/06/1987 F - Formal Settlement  
6. 02001 Other 19100134 B01 09/09/1987 10/14/1987 $0 $0 $0 10/06/1987 -  
7. 02002 Other 19100151 B 09/09/1987 10/14/1987 $0 $0 $0 10/06/1987 -  
8. 02003 Other 19030002 A01 09/09/1987 09/14/1987 $0 $0 $0 10/06/1987 -  

Investigation Summary

Investigation Nr: 14528012
Event: 07/30/1987
TWO EMPLOYEES DIED: SUPPLIED WITH NITROGEN GAS FOR BREATHING

ON JULY 30, 1987, EMPLOYEES #1 AND #2 WERE SAND BLASTING IN A PIT UNDER A WEIGHING SCALE AT A CHEMICAL PLANT. THE EMPLOYEES WORKED FOR A PAINTING CONTRACTOR. THE MEN'S BLASTING EQUIPMENT WAS CONNECTED TO A DIESEL-POWERED MOBILE AIR COMPRESSOR. THEIR ABRASIVE BLASTING RESPIRATORS WERE CONNECTED TO A COMPRESSED AIR LINE IN A BUILDING AT THE CHEMICAL PLANT. THE PLANT LOST POWER AND USE OF ITS AIR COMPRESSORS THE DAY OF THE ACCIDENT. THE COMPRESSED-AIR LINES OF THE BUILDING WERE FILLED WITH PRESSURIZED NITROGEN. THEREFORE THE MEN'S ABRASIVE BLASTING RESPIRATORS WERE SUPPLIED WITH NITROGEN BY BEING CONNECTED TO THE BUILDING'S COMPRESSED AIR LINES. ACCORDING TO THE CORONER THE MEN DIED OF A LACK OF OXYGEN. THERE WAS ENOUGH AMBIENT OXYGEN IN THE PIT TO SUPPORT LIFE SINCE SEVERAL EMPLOYEES ENTERED THE PIT WITHOUT ANY PROBLEM MINUTES AFTER THE ACCIDENT WITHOUT USING RESPIRATORS OR SUPPLIED AIR.

Keywords: OXYGEN DEFICIENCY, RESPIRATORY, NITROGEN, SANDBLASTING, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101250819 Occupation Not Listed
2 101250819 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.