Inspection Detail
Inspection: 101238335 - Monsanto Company
Inspection Information - Office: Cincinnati Area Office
Site Address:
Monsanto Company
River Rd.
Addyston, OH 45001
Mailing Address:
, , 00000
Union Status: Union
SIC:2821
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/23/1988
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/07/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360648000 | ||
| Referral | 901114447 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $3,240 | $0 | $0 | $0 | $0 | $3,240 |
| Current Penalty | $1,480 | $0 | $0 | $0 | $0 | $1,480 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01002 | Serious | 19100132 A | 01/13/1989 | 04/23/1990 | $540 | $900 | $0 | 02/07/1989 | F - Formal Settlement | |
| 2. | 01003 | Serious | 19100307 B | 01/13/1989 | 04/19/1990 | $400 | $900 | $0 | 02/07/1989 | F - Formal Settlement | |
| 3. | 02001 | Serious | 5A0001 | 01/17/1989 | 01/23/1989 | $900 | $900 | $0 | 02/07/1989 | F - Formal Settlement | Citation has been deleted. |
| 4. | 02002A | Serious | 19100132 A | 01/13/1989 | 04/19/1990 | $540 | $540 | $0 | 02/07/1989 | F - Formal Settlement | |
| 5. | 02002B | Serious | 19100134 A01 | 01/13/1989 | 04/19/1990 | $0 | $0 | $0 | 02/07/1989 | F - Formal Settlement | |
| 6. | 02002C | Serious | 19101200 H02 III | 01/13/1989 | 04/19/1990 | $0 | $0 | $0 | 02/07/1989 | F - Formal Settlement |
Investigation Summary
Employee #1 was cleaning prex hopper #13. He opened the door to put a drop light inside. Laying the light on the bottom of the hopper, he then used a water hose to hose down the inside of the hopper. Because the light didn't have a guard, the bulb was exposed. Water hitting and breaking the bulb caused a dust explosion. Employee #1 suffered burns over 30 percent of his body. Ten days later, Employee #1 died. The light was approved for use in a class II hazardous location.
Keywords: BURN, CLEANING, LIGHTING FIXTURE, EXPLOSION, COMBUSTIBLE DUST, HOPPER, WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101238335 | Fatality | Burn/Scald(Heat) | Occupation not reported |
Translate