Inspection Detail
Inspection: 101230019 - Hunt Refining Company, A Corporation
Inspection Information - Office: Birmingham Area Office
Site Address:
Hunt Refining Company, A Corporation
1855 Sanders Ferry Road
Tuscaloosa, AL 35401
Mailing Address:
100 Towncenter Blvd. Suite 300, Tuscaloosa, AL 35406
Union Status: NonUnion
SIC:2911
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/29/1988
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 01/29/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360652267 |
Investigation Summary
At approximately 8:30 p.m. on January 19, 1988, Employee #1, a coker operator, was making inspection rounds in the refinery coker area. Evidently the employee was exposed to a high level of hydrogen sulfide when a coker stabilizer reflux pump seal failed. Employee #1 was found face down 15 feet from a pump that had a blown seal. He was taken by ambulance to the local hospital, where he was pronounced dead on arrival.
Keywords: HYDROGEN SULFIDE, EQUIPMENT FAILURE, SEAL, OVEREXPOSURE, PUMP, ACCIDENTAL DISCHARGE, REFINERY
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101230019 | Fatality | Asphyxia | Occupation not reported |
Translate