Inspection Detail
Inspection: 101208965 - M. A. P. Construction, Inc.
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
M. A. P. Construction, Inc.
3312 Nw North River Drive
Miami, FL 33142
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1629
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 08/05/1987
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 09/21/1987
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360677066 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 5 | ||||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $2,960 | $0 | $0 | $0 | $0 | $2,960 |
Current Penalty | $960 | $0 | $0 | $0 | $0 | $960 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19150007 A01 | 08/26/1987 | 08/30/1987 | $0 | $640 | $0 | I - Informal Settlement | ||
2. | 01002A | Serious | 19150036 A01 | 08/26/1987 | 08/29/1987 | $640 | $640 | $0 | I - Informal Settlement | Citation has been deleted. | |
3. | 01002B | Serious | 19150036 A02 | 08/26/1987 | 08/29/1987 | $320 | $0 | $0 | I - Informal Settlement | ||
4. | 01003 | Serious | 19150052 B01 | 08/26/1987 | 08/29/1987 | $400 | $400 | $0 | I - Informal Settlement | Citation has been deleted. | |
5. | 01004 | Serious | 19150076 A01 | 08/26/1987 | 08/29/1987 | $320 | $640 | $0 | I - Informal Settlement | ||
6. | 01005 | Serious | 19150094 | 08/26/1987 | 08/29/1987 | $320 | $640 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 was spray painting inside the hold of a barge with an airless spray gun. When a coworker began welding the hatch cover of an adjacent hold, a flash fire occurred that burned Employee #1. He died of related causes (bronchial pneumonia) two and one half weeks later.
Keywords: BURN, RESPIRATORY, BARGE, VENTILATION, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, SPRAY PAINTING, WELDING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101208965 | Fatality | Burn/Scald(Heat) | Painters, construction and maintenance |