Inspection Detail
Inspection: 101183150 - Camerota Truck Parts
Inspection Information - Office: Hartford Area Office
Site Address:
Camerota Truck Parts
245 Shaker Road
Enfield, CT 06082
Mailing Address:
P.O. Box 2310, Enfield, CT 06082
Union Status: NonUnion
SIC:5093
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/07/1986
Emphasis:
Case Closed: 02/17/1987
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360666317 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
Current Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100252 D02 VII | 12/16/1986 | 12/19/1986 | $420 | $420 | $0 | - |
Investigation Summary
EMPLOYEE #1 WAS CUTTING UP A TRUCK FRAME, USING A PROPANE CUTTING TORCH. SUDDENLY A NEARBY GAS TANK EXPLODED, KILLING THE EMPLOYEE.
Keywords: FLAMMABLE VAPORS, WORK RULES, TORCH, EXPLOSION, PROPANE, GASOLINE, TANK, CUTTING AND BURNING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 101183150 | Fatality | Burn/Scald(Heat) | Occupation not reported |