Inspection: 101175669 - Weirton Steel Corporation

Inspection Information - Office: Charleston Area Office

 

Inspection Nr: 101175669
Report ID: 0316400
Date Opened: 04/06/1994

Site Address:
Weirton Steel Corporation
400 Three Springs Drive
Weirton, WV 26062

Mailing Address:
, , 00000

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/25/1994

Emphasis:

Case Closed: 08/22/1994


Related Activity
Type Activity Nr Safety Health
Accident 360503668
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $10,000 $0 $0 $0 $0 $10,000
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 E01 06/06/1994 06/24/1994 $5,000 $5,000 $0 -  
2. 01002 Serious 19100147 D05 II 06/06/1994 06/24/1994 $5,000 $5,000 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14482608
Event: 04/06/1994
Mill fire injures 13 employees

During maintenance work on the #19 tandem mill, millwrights, who had disconnected four hydraulic lines, forgot to reconnect them before energizing the hydraulic pumps. Consequently, when the pumps started, hydraulic fluid was sprayed into the atmosphere at the north end of the mill. The atomized hydraulic fluid then came in contact with an electric space heater that was in service approximately 17 feet from the nearest hydraulic line. A flash fire completely engulfed the mill and injured Employees #1, #2, #4, #6, #8, #9, #10, and #12 through #17. Only Employees #2, #4, #6, and #9 were hospitalized.

Keywords: MAINTENANCE, FLAMMABLE LIQUID, HEATER, FIRE, HYDRAULIC FLUID, MILLWRIGHT, MILL--PLANT, ACCIDENTAL DISCHARGE, HYDRAULIC PUMP, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101175669 Non Hospitalized injury Asphyxia Firefighting occupations
2 101175669 Hospitalized injury Burn/Scald(Heat) Millwrights
3 101175669 Non Hospitalized injury Asphyxia Misc. electrical & electronic equipment repairers
4 101175669 Non Hospitalized injury Asphyxia Misc. electrical & electronic equipment repairers
5 101175669 Non Hospitalized injury Asphyxia Misc. electrical & electronic equipment repairers
6 101175669 Hospitalized injury Burn/Scald(Heat) Millwrights
7 101175669 Non Hospitalized injury Asphyxia Millwrights
8 101175669 Non Hospitalized injury Asphyxia Millwrights
9 101175669 Non Hospitalized injury Asphyxia Supervisors, mechanics and repairers
10 101175669 Hospitalized injury Burn/Scald(Heat) Millwrights
11 101175669 Hospitalized injury Burn/Scald(Heat) Supervisors, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.