Inspection: 101159663 - General Services & Construction, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 101159663
Report ID: 0420600
Date Opened: 03/13/1987

Site Address:
General Services & Construction, Inc.
U.S. Hwy 41 South
Gibsonton, FL 33534

Mailing Address:
P.O. Box 3269, Tampa, FL 33601

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/01/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/23/1987


Related Activity
Type Activity Nr Safety Health
Accident 360707442
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $240 $0 $0 $0 $0 $240
Current Penalty $240 $0 $0 $0 $0 $240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260416 A01 04/07/1987 04/17/1987 $240 $240 $0 -  
2. 01001B Serious 19260416 A03 04/07/1987 04/17/1987 $0 $0 $0 -  
3. 02001 Other 19260020 B01 04/07/1987 04/20/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14516363
Event: 03/12/1987
ELECTRIC SHOCK AND FALL - DIRECT CONTACT WITH OVERHEAD LINE

TWO EMPLOYEES WERE WORKING ON A 27-FOOT-BY-15-FOOT-BY-9-FOOT METAL BUILDING, PUTTING SEALANT BETWEEN GROOVES. THEY WERE APPLYING SWEPCO HEAVY DUTY ROOF COATING WITH A BRUSH AND A STRAW-TYPE BROOM. BOTH EMPLOYEES WERE EXPERIENCED IN THIS TYPE OF WORK, HAVING PERFORMED THIS TASK BEFORE. DURING THE COURSE OF THEIR WORK, ONE OF THE EMPLOYEES CONTACTED AN OVERHEAD POWER LINE. HE WAS ELECTROCUTED. THIS EMPLOYEE'S CONTACT WITH THE POWER LINE RESULTED IN AN EXPLOSION, ENGULFING HIM IN FLAMES AND KNOCKING THE OTHER EMPLOYEE FROM THE ROOF OF THE BUILDING. THE EMPLOYEE WHO FELL FROM THE BUILDING RECEIVED A CRUSHED HEEL, FOR WHICH HE WAS HOSPITALIZED.

Keywords: FRACTURE, OVERHEAD POWER LINE, ROOF, ELECTRICAL, ELECTROCUTED, E C, FALL, UNTRAINED, FOOT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101159663 Fatality Electric Shock Occupation not reported
2 101159663 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.