Powered by GoogleTranslate

Inspection Detail

Inspection: 101138956 - Kaiser Tree Preservation Co., Inc.

Inspection Information - Office: Providence Area Office

 

Inspection Nr: 101138956
Report ID: 0112300
Date Opened: 02/12/1986

Site Address:
Kaiser Tree Preservation Co., Inc.
Fire Pole 49, Pojac Point Rd.
North Kingstown, RI 02852

Mailing Address:
37 Flagg Lane, North Kingstown, RI 02852

Union Status: NonUnion

SIC:0783

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/19/1986

Emphasis:

Case Closed: 05/28/1986


Related Activity
Type Activity Nr Safety Health
Accident 360569024
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100067 B04 III 04/11/1986 04/14/1986 $0 $0 $0 -  
2. 01002 Other 19100067 C02 V 04/11/1986 04/23/1986 $0 $0 $0 -  
3. 01003 Other 19100067 C02 IX 04/11/1986 04/23/1986 $0 $0 $0 -  
4. 01004 Other 19100067 C03 04/11/1986 04/28/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14531354
Event: 02/10/1986
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU TREE CUTTER

AN EMPLOYEE WAS USING A 10-FOOT TREE CUTTER FROM THE BUCKET OF AN AERIAL LIFT. THE TREE CUTTER CONTACTED A 4160-VOLT OVERHEAD POWER LINE, ELECTROCUTING THE EMPLOYEE. (THE AERIAL LIFT DID NOT CONFORM TO AMERICAN NATIONAL STANDARD ANSI A92.2-1969.) THE EMPLOYEE HAD NOT BEEN FOLLOWING HIS EMPLOYER'S INSTRUCTIONS.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E GI IC, TREE TRIMMING, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101138956 Fatality Electric Shock Forestry workers, except logging
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.