Inspection Detail
Inspection: 101106656 - Boyles Roofing & Sheetmetal, Inc.
Inspection Information - Office: Jackson Area Office
Site Address:
Boyles Roofing & Sheetmetal, Inc.
Wells Lamont Corp. On Beacon Street
Philadelphia, MS 39350
Mailing Address:
401 Court Street, Waynesboro, MS 39367
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/05/1987
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/20/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360130447 |
Investigation Summary
AN EMPLOYEE WAS REMOVING A METAL LADDER FROM A ROOF WHERE ROOFING WORK HAD BEEN PERFORMED. THE LADDER CONTACTED PARTS OF A TRANSFORMER ENERGIZED AT 13.2 KILOVOLTS, AND THE EMPLOYEE WAS ELECTROCUTED.
Keywords: ELECTRICAL, ELECTROCUTED, LADDER, E C, METAL LADDER, TRANSFORMER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101106656 | Fatality | Electric Shock | Roofers |
Translate