Powered by GoogleTranslate

Inspection Detail

Inspection: 101094100 - Speed World Automotive

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 101094100
Report ID: 0418100
Date Opened: 12/16/1992

Site Address:
Speed World Automotive
7-Ellis Street
Augusta, GA 30901

Mailing Address:
510 Wallace Street, Augusta, GA 30901

Union Status: NonUnion

SIC:7538

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/16/1992

Emphasis:

Case Closed: 04/19/1993


Related Activity
Type Activity Nr Safety Health
Accident 360959324
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 4 4
Initial Penalty $450 $0 $0 $0 $0 $450
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 19101200 E01 02/18/1993 04/16/1993 $0 $450 $0 A - Amendment  
2. 01001B Serious 19101200 G01 02/18/1993 03/16/1993 $0 $0 $0 A - Amendment Citation has been deleted.
3. 01001C Serious 19101200 H 02/18/1993 03/16/1993 $0 $0 $0 A - Amendment Citation has been deleted.
4. 02001 Other 19100037 Q01 02/18/1993 03/16/1993 $0 $0 $0 -  
5. 02002 Other 19100101 B 02/18/1993 03/16/1993 $0 $0 $0 -  
6. 02003 Other 19100253 B02 IV 02/18/1993 03/16/1993 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14332910
Event: 12/12/1992
Employee killed in automotive shop fire

At approximately 3:15 a.m. on December 12, 1992, Employee #1 was apparently smoking and fell asleep in the office of an automotive repair shop. Employee #1 was not working and was not being paid at the time. A nitrous oxide cylinder exploded because the safety relief device did not operate. A fire ensued and two citizens nearby attempted to rescue Employee #1, who suffered fourth degree burns to all parts of his body and was later pronounced dead at the scene. Causal factors may also include failure to mark the exit doors.

Keywords: BURN, FELL ASLEEP, SAFETY RELIEF VALVE, CYLINDER, WORK RULES, FIRE, EQUIPMENT FAILURE, EXPLOSION, SMOKING, NITROUS OXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101094100 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close