Powered by GoogleTranslate

Inspection Detail

Inspection: 101084499 - Dick Fleury Building & Remodeling

Inspection Information - Office: Augusta Area Office

 

Inspection Nr: 101084499
Report ID: 0111100
Date Opened: 05/07/1986

Site Address:
Dick Fleury Building & Remodeling
51 Water Street
Augusta, ME 04330

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1522

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/08/1986

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 07/23/1986


Related Activity
Type Activity Nr Safety Health
Referral 900955949 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 4 3 7
Initial Penalty $360 $0 $0 $0 $0 $360
Current Penalty $360 $0 $0 $0 $0 $360
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260451 A12 05/15/1986 05/21/1986 $80 $80 $0 -  
2. 01002 Serious 19260451 D10 05/15/1986 05/21/1986 $80 $80 $0 -  
3. 01003A Serious 19260451 Y04 III 05/15/1986 05/21/1986 $100 $100 $0 -  
4. 01003B Serious 19260021 B02 05/15/1986 05/21/1986 $0 $0 $0 -  
5. 01004A Serious 19260451 Y11 05/15/1986 05/21/1986 $100 $100 $0 -  
6. 01004B Serious 19260451 Y03 05/15/1986 05/21/1986 $0 $0 $0 -  
7. 02001 Other 19260451 A13 05/15/1986 05/23/1986 $0 $0 $0 -  
8. 02002 Other 19260451 D07 05/15/1986 05/21/1986 $0 $0 $0 -  
9. 02003 Other 19260451 Y05 05/15/1986 05/21/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14477889
Event: 05/07/1986
Two employees injured in 20 ft fall from scaffold

Employees #1 and #2 were at a height of 20 ft installing vinyl siding on a building. They were working from a pump jack scaffold that consisted of three 25 ft poles made of 9 ft and 16 ft 2 by 4s. The poles were braced at 8 and 25 ft off the ground. The middle pole snapped 9 ft from the top, where the 2 by 4s came together, and both employees fell. Employee #1 broke his tailbone and Employee #2 broke his back. If the poles had been braced in accordance with regulation T8CCR 1926.451(y)(4)(iii), a brace would have been located adjacent to where the pole broke.

Keywords: FRACTURE, INSTALLING, WORK RULES, CONSTRUCTION, PUMP JACK SCAFFOLD, EQUIPMENT FAILURE, BACK, FALL, FALL PROTECTION, BRACING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101084499 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
2 101084499 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.