Powered by GoogleTranslate

Inspection Detail

Inspection: 101081404 - Tri-State Contractors Inc.

Inspection Information - Office: Baton Rouge Area Office

 

Inspection Nr: 101081404
Report ID: 0625700
Date Opened: 02/17/1987

Site Address:
Tri-State Contractors Inc.
5377 Highland Rd.
Baton Rouge, LA 70808

Mailing Address:
Po Box 762, Collierville, TN 38027

Union Status: NonUnion

SIC:1794

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/17/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/23/1988


Related Activity
Type Activity Nr Safety Health
Referral 900895624 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 5 8
Current Violations 3 5 8
Initial Penalty $840 $0 $0 $0 $0 $840
Current Penalty $420 $0 $0 $0 $0 $420
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260651 V 03/16/1987 03/19/1987 $140 $280 $0 03/30/1987 R - Review Commission  
2. 01002 Serious 19260651 V 03/16/1987 03/19/1987 $140 $280 $0 03/30/1987 R - Review Commission  
3. 01003 Serious 19100106 B03 IVA 03/16/1987 03/19/1987 $140 $280 $0 03/30/1987 R - Review Commission  
4. 02001 Other 19260028 A 03/16/1987 03/19/1987 $0 $0 $0 03/30/1987 R - Review Commission  
5. 02002 Other 19260102 A01 03/16/1987 03/19/1987 $0 $0 $0 03/30/1987 R - Review Commission  
6. 02003 Other 19260151 A03 03/16/1987 03/19/1987 $0 $0 $0 03/30/1987 R - Review Commission  
7. 02004 Other 19260350 H 03/16/1987 03/19/1987 $0 $0 $0 03/30/1987 R - Review Commission  
8. 02005 Other 19260352 D 03/16/1987 03/19/1987 $0 $0 $0 03/30/1987 R - Review Commission  

Investigation Summary

Investigation Nr: 14391015
Event: 02/17/1987
BURN - EXPLOSION OF GASOLINE VAPORS

TWO EMPLOYEES WERE INSTALLING A SECONDARY VAPOR RECOVERY SYSTEM FOR A GASOLINE PUMP. THREE 12000-GALLON UNDERGROUND GASOLINE TANKS WERE BEING FILLED AT THE SAME TIME. THE VENTING SYSTEM FOR THE GASOLINE VAPORS HAD NOT BEEN COMPLETED BEFORE THE TANKS WERE FILLED. GASOLINE VAPORS WERE ALLOWED TO VENT FROM NINE DIFFERENT PLACES ON THE THREE TANKS WITHIN THE EXCAVATION FOR THE TANKS. THE VAPORS FROM THE TANKS HAD ACCUMULATED FOR ABOUT 4 HOURS. SOME NON-EXPLOSION-PROOF ELECTRIC TOOLS WERE BEING OPERATED AT THE EDGE OF THE EXCAVATION. THE TOOLS IGNITED THE VAPORS, AND A FLASH FIRE RESULTED, SEVERELY BURNING THE TWO EMPLOYEES. BOTH WERE HOSPITALIZED FOR THEIR INJURIES.

Keywords: BURN, CLOTHING, EXCAVATION, ELECTRICAL, E C, EXPLOSION, GASOLINE, EQUIPMENT APPROVAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101081404 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 101081404 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close