Inspection: 100995711 - Conquista Constructors, Inc.

Inspection Information - Office: Austin Area Office

 

Inspection Nr: 100995711
Report ID: 0625400
Date Opened: 09/19/1990

Site Address:
Conquista Constructors, Inc.
8801 S. Flores
San Antonio, TX 78214

Mailing Address:
P. O. Box 1230, Buda, TX 78610

Union Status: NonUnion

SIC:1771

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/11/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/20/1993


Related Activity
Type Activity Nr Safety Health
Accident 360410005
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $2,000 $0 $0 $0 $0 $2,000
Current Penalty $2,000 $0 $0 $0 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B02 11/13/1990 11/19/1990 $700 $700 $0 -  
2. 01002 Serious 19260059 E01 11/13/1990 11/16/1990 $120 $120 $0 -  
3. 01003 Serious 19260059 G01 11/13/1990 11/16/1990 $120 $120 $0 -  
4. 01004 Serious 19260059 H 11/13/1990 11/16/1990 $120 $120 $0 -  
5. 01005 Serious 19260550 A15 I 11/13/1990 11/16/1990 $700 $700 $0 -  
6. 01006A Serious 19260602 A09 I 11/13/1990 11/23/1990 $240 $240 $0 -  
7. 01006B Serious 19260602 A09 II 11/13/1990 11/23/1990 $0 $0 $0 -  
8. 02001 Other 19260152 G09 11/13/1990 11/19/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 773630
Event: 09/18/1990
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

AN EMPLOYEE WAS GUIDING A CONCRETE BUCKET SUSPENDED BY A 22-TON CRANE. THE CRANE CONTACTED A 7900-VOLT OVERHEAD POWER LINE, AND THE EMPLOYEE WAS ELECTROCUTED.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100995711 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.