Powered by GoogleTranslate

Inspection Detail

Inspection: 100977040 - High Tech Steel Erectors

Inspection Information - Office: Concord Area Office

 

Inspection Nr: 100977040
Report ID: 0111700
Date Opened: 02/17/1989

Site Address:
High Tech Steel Erectors
581 Second St.
Manchester, NH 03101

Mailing Address:
Osgood Rd., Milford, NH 03055

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/23/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/25/1989


Related Activity
Type Activity Nr Safety Health
Accident 360516132
Referral 901334631 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 4 4
Initial Penalty $2,100 $0 $0 $0 $0 $2,100
Current Penalty $1,150 $0 $0 $0 $0 $1,150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 03/21/1989 03/24/1989 $325 $450 $0 I - Informal Settlement  
2. 01002 Serious 19260028 A 03/21/1989 03/24/1989 $275 $400 $0 I - Informal Settlement  
3. 01003 Serious 19260416 A03 03/21/1989 03/24/1989 $450 $450 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19260450 A01 03/21/1989 03/24/1989 $275 $400 $0 I - Informal Settlement  
5. 01005 Serious 19260550 A15 I 03/21/1989 03/24/1989 $275 $400 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14529333
Event: 02/17/1989
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

A crane operator and a foreman were setting the outriggers for a 45-ton lattice boom crane. The crane's boom contacted an overhead power line, and the foreman received an electric shock. (The crane operator was uninjured.) The foreman was hospitalized for his injury. He recovered completely.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E GI IA, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100977040 Hospitalized injury Electric Shock Supervisors, material moving equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close