Powered by GoogleTranslate

Inspection Detail

Inspection: 100961135 - Con Del Corporation

Inspection Information - Office: Region 09; San Francisco

 

Inspection Nr: 100961135
Report ID: 0931700
Date Opened: 08/03/1987

Site Address:
Con Del Corporation
35780 Date Palm Drive
Cathedral City, CA 92234

Mailing Address:
41-910 Boardwalk Suite B3, Palm Desert, CA 92260

Union Status: NonUnion

SIC:1751

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 08/18/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/21/1987


Related Activity
Type Activity Nr Safety Health
Accident 360459044
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 6 9
Current Violations 3 6 9
Initial Penalty $1,160 $0 $0 $0 $0 $1,160
Current Penalty $1,160 $0 $0 $0 $0 $1,160
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260405 J02 I 09/08/1987 09/15/1987 $280 $280 $0 -  
2. 01002 Serious 19260403 B01 09/08/1987 09/15/1987 $640 $640 $0 -  
3. 01003 Serious 19260403 E 09/08/1987 09/15/1987 $240 $240 $0 -  
4. 02001 Other 19030002 A01 09/08/1987 09/11/1987 $0 $0 $0 -  
5. 02002 Other 19260020 B01 09/08/1987 09/22/1987 $0 $0 $0 -  
6. 02003 Other 19260020 B02 09/08/1987 09/15/1987 $0 $0 $0 -  
7. 02004 Other 19260051 A04 09/08/1987 09/15/1987 $0 $0 $0 -  
8. 02005 Other 19260404 B01 I 09/08/1987 09/15/1987 $0 $0 $0 -  
9. 02006 Other 19260404 F06 09/08/1987 09/15/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 966549
Event: 07/30/1987
ELECTRIC SHOCK - GROUND FAULT IN SCREW GUN

An employee had been working as a steel stud framer for 6 weeks. He had had several years of experience as a construction carpenter. He was using a Black and Decker 120-volt screw gun (Model No. 2060-09, Type 3) to fasten steel building entry studs together. The power supply cord on the screw gun had been replaced with a 15.2-meter-long, Type SJTW cord and a 15-ampere twist-lock attachment plug. The grounding blade on the attachment plug had been filed off. The employee was using a 20-ampere receptacle on an Abco Hardware spider box to supply electric power to the screw gun. The receptacle outlet was not protected by a ground-fault circuit interrupter. The insulation on the power supply cord on the screw gun was cut 6.1 meters from the handle. The cut had exposed the two circuit conductors. Either the bare conductors contacted the metal frame, or a ground fault energized the frame of the screw gun. The employee was electrocuted when he contacted the metal frame.

Keywords: ELEC INSULATION, ELECTRIC SCREW GUN, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, E C, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC CORD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100961135 Fatality Electric Shock Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close