Inspection Detail
Inspection: 100944826 - Libes Stripping And Refinishing
Inspection Information - Office: Region 09; San Francisco
Site Address:
Libes Stripping And Refinishing
18711 Sherman Way
Reseda, CA 91335
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7641
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/14/1987
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/11/1988
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360457501 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | 8 | |||
Current Violations | 4 | 4 | 8 | |||
Initial Penalty | $600 | $0 | $0 | $0 | $0 | $600 |
Current Penalty | $300 | $0 | $0 | $0 | $0 | $300 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100022 A02 | 12/18/1987 | 12/26/1987 | $80 | $160 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100106 C02 IVA | 12/18/1987 | 12/26/1987 | $80 | $160 | $0 | I - Informal Settlement | ||
3. | 01003 | Serious | 19100151 C | 12/18/1987 | 12/26/1987 | $80 | $160 | $0 | I - Informal Settlement | ||
4. | 01004A | Serious | 19100303 B01 | 12/18/1987 | 12/26/1987 | $60 | $120 | $0 | I - Informal Settlement | ||
5. | 01004B | Serious | 19100305 B02 | 12/18/1987 | 12/26/1987 | $0 | $0 | $0 | - | ||
6. | 02001 | Other | 19100020 G02 | 12/18/1987 | 01/05/1988 | $0 | $0 | $0 | I - Informal Settlement | ||
7. | 02002 | Other | 19100106 D02 III | 12/18/1987 | 12/26/1987 | $0 | $0 | $0 | I - Informal Settlement | ||
8. | 02003 | Other | 19100107 B05 IV | 12/18/1987 | 01/29/1988 | $0 | $0 | $0 | I - Informal Settlement | ||
9. | 02004 | Other | 19101200 E01 | 12/18/1987 | 01/29/1988 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
AT APPROXIMATELY 9:40 AM ON OCTOBER 9, 1987, EMPLOYEE #1 WAS DISCOVERED LYING FACE DOWN IN A DIP TANK CONTAINING ABOUT A 2 INCH DEPTH OF CHLORINATED HYDROCARBON, ALCOHOL BLEND. THE DIP TANK WAS 8 FEET LONG, 4 FEET WIDE AND 37 INCHES DEEP. THE DIP TANK AND SOLVENT WERE USED TO STRIP PAINT FROM FURNITURE. ON THIS DAY, TWO SMALL DOORS HAD BEEN PLACED IN THE TANK. EMPLOYEE #1 HAD BEEN MISSING FOR APPROXIMATELY 10 MINUTES WHEN ANOTHER EMPLOYEE, AWARE OF THE DOORS IN THE TANK AND WISHING TO REMOVE THEM BEFORE THEY WERE DAMAGED BY THE SOLUTION, WENT TO THE TANK AND FOUND EMPLOYEE #1, WITHOUT GLOVES OR A RESPIRATOR, LYING FACE DOWN IN THE SOLUTION. THE MSDS FOR THE DIP TANK SOLUTION STATES THAT EXPOSURE TO CHLORINATED HYDROCARBONS WILL CAUSE ANESTHETIC OR NARCOTIC EFFECTS.
Keywords: PPE, WORK RULES, PAINT SOLVENT, DIP TANK, CHEMICAL VAPOR, DROWN, TOXIC FUMES, RESPIRATOR
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 100944826 | Fatality | Asphyxia | Occupation not reported |