Inspection Detail
Inspection: 100748789 - Temple Petty Construction Inc.
Inspection Information - Office: Denver Area Office
Site Address:
Temple Petty Construction Inc.
Piceance Station, Rio Blanco County Rd. 5
Meeker, CO 81641
Mailing Address:
714 Arrow West Court, Grand Junction, CO 81505
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/03/1993
Emphasis:
Case Closed: 09/20/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 901078329 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 7 | 7 | ||||
| Current Violations | 7 | 7 | ||||
| Initial Penalty | $8,250 | $0 | $0 | $0 | $0 | $8,250 |
| Current Penalty | $4,950 | $0 | $0 | $0 | $0 | $4,950 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C01 | 06/16/1993 | 07/19/1993 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100147 C04 I | 06/16/1993 | 07/19/1993 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19100147 C05 I | 06/16/1993 | 07/19/1993 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19100147 C07 I | 06/16/1993 | 07/19/1993 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19100252 A02 IV | 06/16/1993 | 06/30/1993 | $450 | $750 | $0 | I - Informal Settlement | ||
| 6. | 01006 | Serious | 19100252 A03 I | 06/16/1993 | 06/30/1993 | $450 | $750 | $0 | I - Informal Settlement | ||
| 7. | 01007 | Serious | 19100252 A03 II | 06/16/1993 | 06/30/1993 | $450 | $750 | $0 | I - Informal Settlement |
Investigation Summary
Four subcontractors were working at a compressor station of a natural gas plant. Two employees were welding 6 inch steel pipe in an excavation. Employees #1 and #2 were 21 feet away in another excavation. Employee #1 was outside of the excavation and Employee #2 was cutting a 4 inch dump line with pipe cutters when the pipe released a condensate mixture. The liquid and the vapors came in contact with the arc welding electrodes and ignited, burning Employees #1 and #2. The other two workers were not injured.
Keywords: BURN, EXCAVATION, FLAMMABLE VAPORS, WORK RULES, CONSTRUCTION, WELDING, EXPLOSION, PIPE, WELDING ELECTRODE, ARC WELDING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 100748789 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 100748789 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate