Powered by GoogleTranslate

Inspection Detail

Inspection: 100718006 - Spivey Wire Line Service

Inspection Information - Office: Fort Worth Area Office

 

Inspection Nr: 100718006
Report ID: 0636900
Date Opened: 10/09/1987

Site Address:
Spivey Wire Line Service
6 Miles West Of Graham North Of Hwy 380
Breckenridge, TX 76024

Mailing Address:
Rt 1 Box 73a, Breckenridge, TX 76024

Union Status: NonUnion

SIC:1389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/09/1987

Emphasis:

Case Closed: 03/31/1989


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 5 9
Current Violations 4 5 9
Initial Penalty $2,510 $0 $0 $0 $0 $2,510
Current Penalty $1,255 $0 $0 $0 $0 $1,255
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100109 E01 IV 12/10/1987 12/16/1987 $320 $640 $0 I - Informal Settlement  
2. 01002 Serious 19100109 E01 VII 12/10/1987 12/16/1987 $405 $810 $0 I - Informal Settlement  
3. 01003 Serious 19100109 E01 VIIB 12/10/1987 12/16/1987 $405 $810 $0 I - Informal Settlement  
4. 01004 Serious 19100132 A 12/10/1987 12/16/1987 $125 $250 $0 I - Informal Settlement  
5. 02001 Other 19040008 12/10/1987 12/13/1987 $0 $0 $0 -  
6. 02002 Other 19100109 D01 IV 12/10/1987 12/16/1987 $0 $0 $0 -  
7. 02003 Other 19100109 D02 I 12/10/1987 12/16/1987 $0 $0 $0 -  
8. 02004 Other 19100109 D02 IIA 12/10/1987 12/16/1987 $0 $0 $0 -  
9. 02005 Other 19100109 D02 IVB 12/10/1987 12/16/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 768606
Event: 10/02/1987
EMPLOYEE KILLED IN OIL WELL EXPLOSION

AN OIL WELL EMPLOYEE WAS RIGGING A PERFORATING GUN AT A DRILLING SITE. THE GUN CONSISTED OF 75 TO 100 FEET OF PRIMACORD WRAPPED AROUND A 3 INCH PIECE OF PVC PIPE. THE CHARGE WAS TO BE INITIATED BY A 20 OHM BLASTING CAP. THE EMPLOYEE HAD ARMED THE CHARGE AND WAS TAPING THE CAP TO THE PRIMACORD WHEN THE DEVICE EXPLODED. EMPLOYEE #1, STANDING ABOUT 4 FEET AWAY, WAS KILLED. THE EMPLOYEE WORKING ON THE CHARGE AND 2 EMPLOYEES FROM ANOTHER COMPANY WERE TAKEN TO THE HOSPITAL. THOSE 2 EMPLOYEES HAVE SINCE BEEN RELEASED, BUT THE EMPLOYEE WORKING ON THE CHARGE LOST PART OF HIS RIGHT HAND AND SUFFERED SEVERE BURNS TO HIS CHEST, LEGS AND ARMS. ALL 3 SUFFERED HEARING IMPAIRMENT TO SOME DEGREE. THE EQUIPMENT BEING USED WAS AN INTERNATIONAL LODESTAR DIESEL WIRELINE TRUCK (S/N D0535GHA20018). POSSIBLE CAUSAL FACTORS ARE: THE WIRELINE TRUCK WAS NOT GROUNDED TO THE WELLHEAAD OR PULLING RIG. THE ONAN GENERATOR WAS OPERATING AT THE TIME OF THE EXPLOSION. THE ELECTRICAL SAFETY LOOP WAS NOT REMOVED FROM THE CONTROL PANEL. THE EMPLOYEE WAS NOT PROPERLY TRAINED OR SUPERVISED. STRAY VOLTAGES AND/OR A STATIC DISCHARGE APPEARS TO HAVE INITIATED THE BLAST.

Keywords: BLASTING, STATIC ELECTRICITY, EXPLOSIVES, WORK RULES, EXPLOSION, PERFORATING GUN, OIL WELL PERFORATING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100718006 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close