Powered by GoogleTranslate

Inspection Detail

Inspection: 100653260 - Overly Operating Company

Inspection Information - Office: Corpus Christi Area Office

 

Inspection Nr: 100653260
Report ID: 0626000
Date Opened: 06/23/1987

Site Address:
Overly Operating Company
Hwy. 361, Ferry Landing
Port Aransas, TX 78373

Mailing Address:
D-312 Petroleum Center, San Antonio, TX 78209

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 06/24/1987

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/26/1987


Related Activity
Type Activity Nr Safety Health
Accident 360158976
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 5 7
Current Violations 2 5 7
Initial Penalty $600 $0 $0 $0 $0 $600
Current Penalty $450 $0 $0 $0 $0 $450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 08/07/1987 08/11/1987 $150 $300 $0 I - Informal Settlement  
2. 01001B Serious 19260550 A15 I 08/07/1987 08/11/1987 $0 $0 $0 I - Informal Settlement Citation has been deleted.
3. 01002 Serious 19260416 A01 08/07/1987 08/11/1987 $300 $300 $0 -  
4. 02001 Other 19030002 A01 08/07/1987 08/11/1987 $0 $0 $0 -  
5. 02002 Other 19040002 A 08/07/1987 08/12/1987 $0 $0 $0 -  
6. 02003 Other 19260050 C 08/07/1987 08/17/1987 $0 $0 $0 -  
7. 02004 Other 19260050 D01 08/07/1987 08/17/1987 $0 $0 $0 -  
8. 02005 Other 19260051 A04 08/07/1987 08/11/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14402267
Event: 06/19/1987
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

Two employees were removing a lighting pole. The pole had two arms with a lighting fixture on each arm. The pole was 12.8 meters (42 feet) high and 6.4 meters (21 feet) away from a 7200-volt overhead power line. The power line was located 8.8 meters (29 feet) above the ground. A crane raised the pole so that it could clear its mounting bolts and then moved the pole until it was about 4.6 meters (15 feet) away from the power lines before lowering it. One of the employees was standing on the base of the pole as it was being lowered. The other employee was standing about 0.6 meters (2 feet) from the pole as the top of the light contacted the overhead line. This employee received an electric shock and fell onto his right side, contacting the energized pole. He was electrocuted. The employee at the base of the pole jumped free of the pole. However, he also received an electric shock and sustained burns to his hand as he tried to pull his coworker from the pole.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTRIC SHOCK, BURN, ELECTROCUTED, LOAD LINE, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100653260 Fatality Electric Shock Occupation not reported
2 100653260 Non Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.