Inspection Detail
Inspection: 100634203 - Thompson Components - Mostek Corp.
Inspection Information - Office: Dallas Area Office
Site Address:
Thompson Components - Mostek Corp.
1310 Electronics Drive
Carrollton, TX 75006
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3674
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/12/1987
Emphasis:
Case Closed: 06/12/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360335087 |
Investigation Summary
On May 4, 1987, a fire broke out in the diffusion furnace area of fabrication area #6, located on the first floor of the Electronics 2 building in Carrollton, TX. Sixty-seven employees were sent to the local hospital and Employees #1 through #7 were held overnight for observation. The probable cause of the fire was the heating element present in the polypropylene hood. None of the hospitalized employees had any serious problems, and all of them were released the next day.
Keywords: FURNACE, RESPIRATORY, FIRE, INHALATION, MECH MALFUNCTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 100634203 | Hospitalized injury | Other | Occupation not reported | ||
| 2 | 100634203 | Hospitalized injury | Other | Occupation not reported | ||
| 3 | 100634203 | Hospitalized injury | Other | Occupation not reported | ||
| 4 | 100634203 | Hospitalized injury | Other | Occupation not reported | ||
| 5 | 100634203 | Hospitalized injury | Other | Occupation not reported | ||
| 6 | 100634203 | Hospitalized injury | Other | Occupation not reported | ||
| 7 | 100634203 | Hospitalized injury | Other | Occupation not reported |