Powered by GoogleTranslate

Inspection Detail

Inspection: 100582550 - Tc Noe Oil Account

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 100582550
Report ID: 0626300
Date Opened: 10/12/1988

Site Address:
Tc Noe Oil Account
W H Siler Lease, Well #121
Price, TX 75687

Mailing Address:
P. O. Box 245, Selman City, TX 75689

Union Status: NonUnion

SIC:1311

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/21/1988

Emphasis:

Case Closed: 01/24/1989


Related Activity
Type Activity Nr Safety Health
Accident 360335269
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $360 $0 $0 $0 $0 $360
Current Penalty $360 $0 $0 $0 $0 $360
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100027 D05 12/29/1988 01/04/1989 $160 $160 $0 -  
2. 01002 Serious 19100106 E06 I 12/29/1988 01/04/1989 $200 $200 $0 -  

Investigation Summary

Investigation Nr: 14401327
Event: 10/06/1988
One killed, one injured in oil well fire

Employees #1 and #2 were servicing an oil well. While they were returning tubing to the hole, the well kicked back and a cloud of gas escaped. A pumper truck that was located near the well pumping out the cellar became engulfed by the gas cloud. The pumper ignited, resulting in a fire that killed Employee #1 and injured Employee #2.

Keywords: KICK BACK, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, FIRE, OIL WELL DRILLING, GAS, CHEMICAL VAPOR, ACCIDENTAL DISCHARGE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100582550 Fatality Burn/Scald(Heat) Supervisors, extractive occupations
2 100582550 Hospitalized injury Burn/Scald(Heat) Supervisors, extractive occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.