Inspection Detail
Inspection: 1005020.015 - Global Hvac Distributors, Inc.
Inspection Information - Office: Fresno District Office
Site Address:
Global Hvac Distributors, Inc.
27648 Road 92
Visalia, CA 93277
Mailing Address:
310 Sequel Way, Sunnyvale, CA 94085
Union Status: NonUnion
SIC:
NAICS: 423730/Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/14/2014
Emphasis:
Case Closed: 10/28/2015
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 909783 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $5,000 | $0 | $5,000 |
Current Penalty | $0 | $0 | $0 | $2,750 | $0 | $2,750 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 342(A) | 11/20/2014 | $2,750 | $5,000 | $0 | 01/02/2015 | F - Formal Settlement |
Investigation Summary
At 12:00 p.m. on September 4, 2014, an employee was working in the attic of a private residence to evaluate the condition of the HVAC system when he became ill. He began vomiting, collapsed and died. The incident investigation revealed that the employee died as a result of a ruptured cerebral aneurism.
Keywords: Aneurism, Attic, Repair, Residential Construction
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1005020.015 | 43 | M | Fatality | Sales workers, hardware and building supplies |