Powered by GoogleTranslate

Inspection Detail

Inspection: 100490879 - Lewis H. Worrade Corp.

Inspection Information - Office: Parsippany Area Office

 

Inspection Nr: 100490879
Report ID: 0214200
Date Opened: 06/23/1989

Site Address:
Lewis H. Worrade Corp.
Garrabrant & W. Passaic Ave.
Bloomfield, NJ 07003

Mailing Address:
55 Coldenham Road, P.O. Box 423, Walden, NY 12586

Union Status: Union

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/07/1989

Emphasis:

Case Closed: 01/18/1990


Related Activity
Type Activity Nr Safety Health
Accident 360661300
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,000 $0 $0 $0 $0 $1,000
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260950 C01 12/01/1989 12/04/1989 $600 $1,000 $0 I - Informal Settlement  
2. 02001 Other 19030002 A01 12/01/1989 12/04/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14308233
Event: 06/22/1989
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

A JOURNEYMAN POWER LINE WORKER WAS REPLACING CONDUCTORS ON A THREE-PHASE, 4160-VOLT OVERHEAD POWER LINE. HE AND A THIRD-STEP APPRENTICE WERE WORKING FROM THE TWO-PERSON BUCKET OF A HIGH RANGER AERIAL LIFT (MODEL NUMBER UTL-5EI-48) MOUNTED ON AN INTERNATIONAL TRUCK. THEY WERE WORKING NEXT TO A UTILITY POLE. THE APPRENTICE WAS WEARING RUBBER INSULATING GLOVES AND SLEEVES, BUT THE LINE WORKER WAS WEARING RUBBER SLEEVES WITH LEATHER WORK GLOVES ONLY. HIS RUBBER GLOVES WERE INSIDE THE BUCKET. THE APPRENTICE WAS REPLACING THE COPPER CONDUCTORS WITH ALUMINUM ONES. THE LINE WORKER HAD RELOCATED TWO OF THE PHASE CONDUCTORS AND WAS RELOCATING THE THIRD ONE NEAR THE CENTER OF THE WOOD CROSSARM. AS HE LIFTED THE CONDUCTOR WITH HIS LEFT HAND, HE REACHED UP WITH HIS RIGHT HAND, AS IF TO GET MORE LEVERAGE, AND CONTACTED THE INSULATOR BRACKET ON THE POLE. THE EMPLOYEE WAS ELECTROCUTED. THE APPRENTICE PULLED THE LINE WORKER OFF THE ENERGIZED CONDUCTOR AND WAS NOT INJURED. THE LINE WORKER HAD BEEN WORKING WITH HIS EMPLOYER FOR ABOUT 14 MONTHS AND HAD CLAIMED 25 YEARS PRIOR EXPERIENCE.

Keywords: ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, POWER LINE WORKER, ELECTROCUTED, E PTD, ELEC UTILITY WORK, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100490879 Fatality Electric Shock Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.