Powered by GoogleTranslate

Inspection Detail

Inspection: 100381151 - Riley Stoker Corporation

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 100381151
Report ID: 0420600
Date Opened: 11/25/1985

Site Address:
Riley Stoker Corporation
Teco Gannon Plant, Port Sutton Rd
Tampa, FL 33619

Mailing Address:
4108 Park Road, Suite 315, Charlotte, NC 28209

Union Status: Union

SIC:1796

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/12/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/21/1986


Related Activity
Type Activity Nr Safety Health
Accident 360146187
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 1 6
Current Violations 4 1 1 6
Initial Penalty $2,400 $0 $1,000 $0 $0 $3,400
Current Penalty $1,400 $0 $500 $0 $0 $1,900
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260450 A01 01/22/1986 01/25/1986 $200 $400 $0 I - Informal Settlement  
2. 01002 Serious 19260451 D10 01/22/1986 01/25/1986 $200 $400 $0 I - Informal Settlement  
3. 01003A Serious 19260451 A03 01/22/1986 01/25/1986 $500 $800 $0 I - Informal Settlement  
4. 01003B Serious 19260451 I05 01/22/1986 01/25/1986 $0 $0 $0 -  
5. 01003C Serious 19260451 I07 01/22/1986 01/25/1986 $0 $0 $0 -  
6. 01004A Serious 19260451 I08 01/22/1986 01/25/1986 $500 $800 $0 I - Informal Settlement  
7. 01004B Serious 19260451 I08 01/22/1986 01/25/1986 $0 $0 $0 -  
8. 02001 Repeat 19260451 D13 01/22/1986 01/28/1986 $500 $1,000 $0 I - Informal Settlement  
9. 03001 Other 19260500 C01 I 01/22/1986 01/25/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14346555
Event: 11/24/1985
Employee killed in fall from collapsing scaffold

Employee #1, a journeyman boilermaker, was on a two point suspension scaffold refurbishing an electricity-generating boiler. An improperly rigged overhead wire rope attachment gave way, causing one end of the scaffold to collapse. One crew member was able to save himself by grabbing nearby regeat (sic) tubes, but Employee #1 fell about 30 feet to an interior deck and was killed. A crescent wrench had been used to tighten the nuts on fist grip-type wire rope clips. No wire rope thimble had been used in the connection assembly. No regular or daily inspections had been made following the initial installation, although the scaffolding had been in use for about ten days. No safety lines or safety belts were being used.

Keywords: ATTACHMENT HOOK, WIRE ROPE, INADEQUATE MAINT, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, TWO PT SUSP SCAFFOLD, FALL, FALL PROTECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100381151 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close