Inspection Detail
Inspection: 100377753 - Inscho-Kirlin, Inc.
Inspection Information - Office: Tampa Area Office
Site Address:
Inscho-Kirlin, Inc.
9001 W. International Drive
Orlando, FL 32830
Mailing Address:
P. O. Box 22796, Lake Buena Vista, FL 32830
Union Status: Union
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/12/1986
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 07/09/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360146716 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 1 | 3 | ||
Current Violations | 1 | 1 | 1 | 3 | ||
Initial Penalty | $400 | $0 | $200 | $0 | $0 | $600 |
Current Penalty | $200 | $0 | $200 | $0 | $0 | $400 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260500 D01 | 05/16/1986 | 05/18/1986 | $200 | $400 | $0 | I - Informal Settlement | ||
2. | 02001 | Repeat | 19260401 C | 05/16/1986 | 05/18/1986 | $200 | $200 | $0 | - | ||
3. | 03001 | Other | 19040002 A | 05/16/1986 | 05/23/1986 | $0 | $0 | $0 | - |
Investigation Summary
An employee was cutting a section from a 76-millimeter-diameter (3-inch-diameter) copper pipe with a Milwaukee portable electric band saw. He was standing on a plank 3.5 meters (11.5 feet) above the floor. He had previously cut into the pipe without draining the water from it, and the band saw became wet and developed a ground fault. Other employees, who were working at ground level, added an ungrounded extension cord to the temporary circuit, breaking the continuity of the equipment grounding conductor. When the first employee picked up the band saw, he received an electric shock and yelled to the other employees to unplug it. When they did, the injured employee fell to the floor. The ground-fault circuit interrupter in the temporary circuit failed to open the circuit in response to the ground fault. The employee died of electrocution.
Keywords: E GI V, ELECTRICAL, CORD SET, ELECTROCUTED, ELECTRIC SAW, GROUND FAULT, EQUIPMENT GROUNDING, WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 100377753 | Fatality | Electric Shock | Occupation not reported |