Powered by GoogleTranslate

Inspection Detail

Inspection: 100363803 - Phillips Sand & Gravel Company

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 100363803
Report ID: 0418100
Date Opened: 07/29/1986

Site Address:
Phillips Sand & Gravel Company
5489 White Road
College Park, GA 30349

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5039

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/26/1986

Emphasis:

Case Closed: 10/10/1986


Related Activity
Type Activity Nr Safety Health
Accident 360144521
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $240 $0 $0 $0 $0 $240
Current Penalty $240 $0 $0 $0 $0 $240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100177 G12 09/09/1986 10/14/1986 $240 $240 $0 -  
2. 01001B Serious 19100177 G 09/09/1986 10/14/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 606178
Event: 07/29/1986
SINGLE PIECE RIM WHEEL TIRE EXPLOSION

EMPLOYEE #1 WAS EMPLOYED BY A HAULING-FOR-HIRE COMPANY. A TIRE WAS NEEDED FOR A DUMP TRUCK. THE TWO AVAILABLE RIMS HAD CRACKS IN THEM. EMPLOYEE #1 WAS TOLD THAT NEW OR USED RIMS WOULD BE PURCHASED RIGHT AWAY. AS SOON AS HE WAS ALONE, HE DECIDED TO REPAIR THE CRACKS IN THE TWO RIMS WITH AN ARC WELDER. HE MADE THE REPAIRS, THEN MOUNTED AND INFLATED THE TIRES TO 105 PSI. (THE TIRES ARE STAMPED 85 PSI.) THE FOREMAN RETURNED WITH USED RIMS HE HAD PURHASED. EMPLOYEE #1 MOUNTED TIRES ON THESE RIMS, THEN CHECKED ON THE TWO TIRES HE HAD REPAIRED. ONE TIRE WAS DOWN TO 90 PSI. HE FOUND A SMALL LEAK IN THE WELD. HE ROLLED THE TIRE OVER TO THE ARC WELDER AND STRUCK THE AREA THREE TIMES VERY QUICKLY WITH THE ELECTRODE. HE THEN ROLLED THE TIRE ABOUT 100 FEET OUTSIDE THE SHOP AND AROUND TO THE SIDE. HE USED A WATER HOSE TO COOL THE RIM AND THEN CHECKED FOR LEAKS. HE REPLACED THE WATER HOSE AND, AS HE TURNED BACK TOWARD THE TIRE, IT EXPLODED. THE FORCE OF THE EXPLOSION THREW HIS BODY TO THE ROOF OF THE BUILDING, APPROXIMATELY 30 FEET OFF THE GROUND. EMPLOYEE #1 SUFFERED MASSIVE HEAD AND CHEST INJURIES. CRACKED, BROKEN OR DAMAGED RIMS SHOULD BE REMOVED FROM SERVICE. THE TIRE WAS OVER-INFLATED. PROPER SAFETY PROCEDURES WERE NOT FOLLOWED.

Keywords: MAINTENANCE, SINGLE PIECE RIM, WELDING, EXPLOSION, OVERHEATED, ARC WELDING, TIRE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100363803 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.