Powered by GoogleTranslate

Inspection Detail

Inspection: 100360692 - Craftsman Door Company

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 100360692
Report ID: 0418100
Date Opened: 08/15/1986

Site Address:
Craftsman Door Company
226 Luckie Street
Atlanta, GA 30303

Mailing Address:
4191 Mountain Glen Trace - P. O. Box 3100, Lithonia, GA 30058

Union Status: NonUnion

SIC:1751

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/15/1986

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/21/1986


Related Activity
Type Activity Nr Safety Health
Referral 900965930 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $150 $0 $0 $0 $0 $150
Current Penalty $150 $0 $0 $0 $0 $150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B02 09/29/1986 10/07/1986 $150 $150 $0 -  

Investigation Summary

Investigation Nr: 14542542
Event: 08/15/1986
FLAMMABLE VAPORS IGNITED BY SPARKS FROM GRINDER

CONTRACTOR EMPLOYEES WERE INSTALLING A NEW OVERHEAD DOOR IN A ROOM 26 FEET LONG BY 12 FEET, 7 INCHES WIDE. THEY WERE USING A PORTABLE GRINDER TO NOTCH OUT THE OVERHEAD DOOR TRACK. IT WAS ABOUT 1:30 PM ON AUGUST 15, 1986. FLAMMABLE LIQUIDS HAD BEEN STORED AT ONE END OF THE ROOM. A SPARK FROM THE GRINDER APPARENTLY IGNITED THE FLAMMABLE VAPORS, CAUSING A FIRE WHICH BURNED BOTH EMPLOYEES. THE CONTRACTOR EMPLOYEES WERE NEVER INFORMED BY THE PLANT THAT FLAMMABLE LIQUIDS WERE STORED IN THE ROOM. THE CONTRACTOR EMPLOYEES NOTICED THE DRUMS BUT NEVER ASKED WHAT THEY CONTAINED. THE CHEMICALS WERE LOCATED AT A PRINTING PLANT. EMPLOYEES #1 AND #2 WERE BOTH HOSPITALIZED WITH SECOND AND THIRD DEGREE BURNS.

Keywords: FLAMMABLE VAPORS, WORK RULES, SPARK, BURN, GRINDER, FIRE, CONSTRUCTION, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100360692 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 100360692 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close