Inspection Detail
Inspection: 1003523.015 - Stanton Wash Systems, Inc.
Inspection Information - Office: Allentown Area Office
Site Address:
Stanton Wash Systems, Inc.
50 Richard Road
Ivyland, PA 18974
Mailing Address:
50 Richard Road, Ivyland, PA 18974
Union Status: NonUnion
SIC:
NAICS: 333318
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/22/2015
Emphasis:
Case Closed: 04/08/2015
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 917194 | Yes | |
| Accident | 921572 |
Investigation Summary
At 2:15 p.m. on October 24, 2014, an employee was building a water pump assembly for a tire wash system. The 74 inch assembly consisted of a Baldor-Reliance Industrial Motor (Spec #10F823X656G1) mounted on top of a Goulds Water Technology e-SV pump (Cat #46SV71GR4F20). The pump end of the assembly was bolted to two pieces of 3 inch by 2 inch lumber and 31 inches and 34 inches in length. The motor pump assembly fell over and pinned the employee on their side. The employee was killed from right rib fractures, bilateral pulmonary contusion, and right pneumothorax and anoxic injuries.
Keywords: Crushed, Pinned, Suffocated
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1003523.015 | 23 | M | Fatality | Laborers, except construction |