Barker'S Junkyard And Garage, Incorporated
855 Belmont Road
Mulberry, FL 33860

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5932

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/25/1985

Emphasis:

Case Closed: 11/01/1985


Related Activity
Type Activity Nr Safety Health
Accident 360710651
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations
Initial Penalty $700 $0 $0 $0 $0 $700
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 G02 I 10/21/1985 10/24/1985 $350 $350 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19100304 F04 10/21/1985 10/24/1985 $350 $350 $0 I - Informal Settlement Citation has been deleted.
3. 02001 Other 19040008 10/21/1985 10/24/1985 $0 $0 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14346373
Event: 09/04/1985
ELECTRIC SHOCK - GROUND FAULT IN BATTERY CHARGER

AN EMPLOYEE WAS REMOVING THE REAR WHEELS FROM A CAR IN A JUNK YARD. A BATTERY CHARGER WAS CHARGING THE BATTERY IN THE CAR. THE ATTACHMENT PLUG FOR AN EXTENSION CORD SET BEING USED TO SUPPLY POWER TO THE BATTERY CHARGER WAS MISSING ITS GROUNDING BLADE, SO THE CHARGER WAS NOT GROUNDED. ADDITIONALLY, THE ATTACHMENT PLUG WAS MISSING FROM THE CHARGER'S POWER SUPPLY CORD, AND THE BATTERY CHARGER WAS CONNECTED TO THE CORD CONNECTOR ON THE CORD SET BY THE THREE BARE CONDUCTORS ON THE END OF THE POWER SUPPLY CORD. A GROUND FAULT (EITHER IN THE CONNECTION OF THE BARE CONDUCTORS OR INTERNAL TO THE CHARGER) ENERGIZED THE FRAME OF THE CAR, AND THE EMPLOYEE WAS ELECTROCUTED AS HE WAS LOOSENING THE LUG NUTS ON ONE OF THE WHEELS.

Keywords: E GI V, ELECTRICAL, BATTERY CHARGER, CORD SET, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, ELECTRIC CORD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100349240 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.