Powered by GoogleTranslate

Inspection Detail

Inspection: 100342930 - St. Joe Paper Co.

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 100342930
Report ID: 0419700
Date Opened: 01/21/1986

Site Address:
St. Joe Paper Co.
U.S. Highway #98
Port St. Joe, FL 32456

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2621

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/22/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/22/1986


Related Activity
Type Activity Nr Safety Health
Accident 360713150

Investigation Summary

Investigation Nr: 14517858
Event: 01/13/1986
EMPLOYEE BURNED BY STEAM RELEASED FROM RUPTURED EVAPORATOR

ON JANUARY 13, 1986, AN EVAPORATOR RUPTURED AT THE ST. JOE PAPER COMPANY, LOCATED AT PORT ST. JOE, FLORIDA. EMPLOYEE #1 WAS SCALDED BY THE BOILING WATER RELEASED AS A RESULT OF THE RUPTURE. HE DIED OF SEVERE AND EXTENSIVE BURNS TWO DAYS LATER.

Keywords: BURN, RUPTURE, STEAM, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100342930 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.