Inspection: 100296474 - Dowell Schlumberger Co., Inc.
Inspection Information - Office: Austin Area Office
Site Address:
Dowell Schlumberger Co., Inc.
28 Miles Se Of Rock Springs
Rock Springs, TX 78880
Mailing Address:
P. O. Box 4378, Houston, TX 77210
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/21/1985
Emphasis: L:Oilgas
Case Closed: 08/21/1985
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360549471 |
Investigation Summary
EMPLOYEE #1, A SUPERVISOR/CREW CHIEF, WAS STRUCK ON THE HEAD BY A 20 FOOT LONG PIECE OF FIBERGLASS PIPE AND ATTACHED THREADED CONNECTIONS. THE CREW WAS INSTALLING FIBERGLASS CASING BEFORE CEMENTING. HIGH PRESSURE CAUSED THE CASING AND THREADING CONNECTIONS TO SHOOT OUT OF THE GROUND. EMPLOYEE #1 WAS WEARING A HARD HAT. THE ACCIDENT OCCURRED ON AUGUST 10, 1985. EMPLOYEE #1 DIED IN THE HOSPITAL ON AUGUST 18, 1985.
Keywords: HEAD, HIGH PRESSURE, OIL WELL SERVICING, PIPE, STRUCK BY, FALLING OBJECT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 100296474 | Fatality | Concussion | Occupation not reported |