Inspection Detail
Inspection: 100274992 - Pioneer Construction
Inspection Information - Office: Dallas Area Office
Site Address:
Pioneer Construction
240 Nw Newton
Burleson, TX 76028
Mailing Address:
Rt 2 Box 510, Alvarado, TX 76009
Union Status: NonUnion
SIC:1791
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/25/1985
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/01/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 900875246 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $350 | $0 | $0 | $0 | $0 | $350 |
| Current Penalty | $350 | $0 | $0 | $0 | $0 | $350 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260021 B02 | 12/18/1985 | 12/21/1985 | $350 | $350 | $0 | - |
Investigation Summary
AN EMPLOYEE WORKING AT A CONSTRUCTION SITE WAS HANDLING AN ANGLE IRON (20.2 FEET LONG, 1.625 INCHES WIDE) AT THE TOP OF A FRAME BUILDING. THE ANGLE IRON CONTACTED A 7200-VOLT OVERHEAD POWER LINE THAT WAS 50 INCHES AWAY, AND THE EMPLOYEE RECEIVED AN ELECTRIC SHOCK FOR WHICH HE WAS HOSPITALIZED. THE EMPLOYEE HAD BEEN GIVEN NO ELECTRICAL PROTECTIVE EQUIPMENT, AND THE POWER TO THE OVERHEAD LINE HAD NOT BEEN DEENERGIZED.
Keywords: METAL RAIL, OVERHEAD POWER LINE, ELECTRICAL, CONSTRUCTION, E C, ELECTRIC SHOCK, UNTRAINED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 100274992 | Hospitalized injury | Electric Shock | Occupation not reported |
Translate