Powered by GoogleTranslate

Inspection Detail

Inspection: 100268507 - Dressen Industries Clark Div

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 100268507
Report ID: 0626600
Date Opened: 11/12/1985

Site Address:
Dressen Industries Clark Div
9822 Laporte Fwy
Houston, TX 77017

Mailing Address:
Po Box 1818, Houston, TX 77252

Union Status: NonUnion

SIC:3563

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/20/1985

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/14/1986


Related Activity
Type Activity Nr Safety Health
Accident 360141170
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 3 3 6
Initial Penalty $1,080 $0 $0 $0 $0 $1,080
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100184 C04 12/03/1985 12/11/1985 $200 $360 $0 12/27/1985 F - Formal Settlement  
2. 01002 Serious 19100184 C09 12/03/1985 12/09/1985 $200 $360 $0 12/27/1985 F - Formal Settlement  
3. 01003A Serious 19100184 D 12/03/1985 12/11/1985 $200 $360 $0 12/27/1985 F - Formal Settlement  
4. 01003B Serious 19100184 D 12/03/1985 12/11/1985 $0 $0 $0 12/27/1985 -  
5. 02001 Other 19040002 A 12/03/1985 01/07/1986 $0 $0 $0 12/27/1985 -  
6. 02002 Other 19100184 E03 II 12/03/1985 12/11/1985 $0 $0 $0 12/27/1985 -  
7. 02003 Other 19100184 I01 12/03/1985 12/11/1985 $0 $0 $0 12/27/1985 -  

Investigation Summary

Investigation Nr: 14498380
Event: 11/08/1985
One killed, one injured when struck by compressor head

Employees #1 and #2 were installing inlet guides in a 14,000 lb, size 3 Clark MX compressor head, serial #3X-6-1421. The compressor head was suspended above the employees with a P & H mobile crane, model 650. Part of the support rigging was a 1 in. nylon web sling that had a load capacity of 6,200 lb in the configuration being used. Another part of the lifting device was a chain fall rated at 10,000 lb. The nylon sling failed and the compressor head fell, striking both employees. Employee #1 was killed and Employee #2 suffered severe head lacerations.

Keywords: HEAD, INSTALLING, WORK RULES, MOBILE CRANE, OVERLOADED, EQUIPMENT FAILURE, LACERATION, STRUCK BY, SLING, FALLING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100268507 Fatality Other Occupation not reported
2 100268507 Non Hospitalized injury Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close