Inspection Detail
Inspection: 100216613 - General Electric Co. (Silicone Products Div)
Inspection Information - Office: Albany Area Office
Site Address:
General Electric Co. (Silicone Products Div)
Route 4 & Route 32
Waterford, NY 12188
Mailing Address:
Route 4 & Route 32, Waterford, NY 12188
Union Status: Union
SIC:2822
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/16/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/04/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360525935 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $1,120 | $0 | $0 | $0 | $0 | $1,120 |
Current Penalty | $1,120 | $0 | $0 | $0 | $0 | $1,120 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 12/18/1985 | 12/21/1985 | $560 | $560 | $0 | 01/15/1986 | J - ALJ Decision | |
2. | 01002 | Serious | 19100132 A | 12/18/1985 | 12/21/1985 | $560 | $560 | $0 | - |
Investigation Summary
EMPLOYEE #1 WAS POURING FLAMMABLE LIQUID FROM ONE 55 GALLON DRUM INTO ANOTHER WHEN THE LIQUID EXPLODED, CAUSING SECOND AND THIRD DEGREE BURNS TO 52% OF HIS BODY. THE FLAMMABLE LIQUID WAS HEXAMETHYLDISILAZANE (FLASH POINT-5% FARENHEIT). THE LIQUID WAS BEING TRANSFERED TO MEASURE OUT 65 POUNDS,WHICH WAS TO BE ADDED TO A RUBBER GUM COMPOUND TO PRODUCE A SILICONE RUBBER.
Keywords: BURN, FLAMMABLE LIQUID, LOW FLASH POINT, EXPLOSION, HEXAMETHYLDISILAZANE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 100216613 | Fatality | Burn/Scald(Heat) | Occupation not reported |